1. About this Document  
1.1 Change Control  
1.1.1 Current Status  
Revision 1.6  
1.1.2 Change History  
Issue  
Date  
By  
Change  
Draft 0.0  
30.06.00 F. Hartwich First Draft  
Revision 0.1  
Revision 0.2  
Revision 1.0  
Revision 1.1  
Revision 1.2  
Revision 1.3  
Revision 1.4  
Revision 1.5  
Revision 1.6  
12.01.01 F. Hartwich Gap Control  
21.10.00 F. Hartwich Trigger Memory  
29.11.00 F. Hartwich Cycle Count, Global Time Mark  
11.12.00 F. Hartwich TUR Configuration, Enable Local Time  
13.12.00 F. Hartwich Time Mark Register, TMC  
17.01.01 F. Hartwich TUR Configuration Registers  
30.04.01 F. Hartwich Clock Synch., Stop_Watch, External Events  
12.10.01 F. Hartwich Editorial changes  
11.11.02 F. Hartwich Watchdog, Gap Control, Global Time Preset  
1.2 Conventions  
The following conventions are used within this User’s Manual.  
Helvetica bold  
Names of bits and signals  
States of bits and signals  
Helvetica italic  
1.3 Scope  
This document describes the TTCAN IP module and its features from the application  
programmer’s point of view.  
All information necessary to integrate the TTCAN IP module into an user-defined ASIC is  
located in the ‘Module Integration Guide’.  
1.4 References  
This document refers to the following documents.  
Ref  
1
Author(s) Title  
FV/SLN1  
K8/EIS1  
K8/EIS1  
ISO  
CAN Specification Revision 2.0  
2
Module Integration Guide  
3
VHDL Reference CAN User’s Manual  
4
ISO 11898-1 “Controller Area Network (CAN) - Part 1:  
Data link layer and physical signalling”  
5
ISO  
ISO 11898-4 “Controller Area Network (CAN) - Part 4:  
Time triggered communication”  
BOSCH  
- 6/77 -  
11.11.02  
 
             
User’s Manual  
TTCAN  
Revision 1.6  
1.5 Terms and Abbreviations  
This document uses the following terms and abbreviations.  
Term  
CAN  
BSP  
BTL  
Meaning  
Controller Area Network  
Bit Stream Processor  
Bit Timing Logic  
CRC  
DLC  
EML  
FSE  
Cyclic Redundancy Check Register  
Data Length Code  
Error Management Logic  
Frame Synchronisation Entity  
Finite State Machine  
Network Time Unit  
FSM  
NTU  
TTCAN  
Time Triggered CAN  
BOSCH  
- 7/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
2. Functional Description  
2.1 Functional Overview  
The TTCAN is a CAN IP module that can be integrated as stand-alone device or as part of an  
ASIC. It is described in VHDL on RTL level, prepared for synthesis. It consists of the  
components (see figure 1) CAN_Core, Message RAM, Message Handler, Control Registers,  
Module Interface, and, for the time triggered function, Trigger Memory and Frame  
Synchronisation Entity.  
The TTCAN performs CAN protocol communication according to ISO 11898-1 (identical to  
Bosch CAN protocol specification 2.0 A, B) and according to ISO 11898-4 : “Time triggered  
communication on CAN”. The bit rate can be programmed to values up to 1MBit/s depending  
on the used technology. Additional transceiver hardware is required for the connection to the  
physical layer (the CAN bus line).  
TTCAN provides all features of time triggered communication specified in ISO 11898-4,  
including event synchronised time triggered communication, global system time, and clock  
drift compensation. Optionally, it may be restricted to the functions of ISO 11898-1, with the  
same features as the Bosch C_CAN IP module.  
For communication on a CAN network, individual Message Objects are configured. The  
Message Objects and Identifier Masks are stored in the Message RAM. The time triggers  
defining the transmission schedule are stored in the Trigger RAM.  
All functions concerning the handling of messages are implemented in the Message Handler.  
Those functions are acceptance filtering, transfer of messages between the CAN_Core and  
the Message RAM, and the handling of transmission requests as well as the generation of the  
module interrupt.  
All functions concerning the time schedule and the global system time are implemented in the  
Frame Synchronisation Entity FSE.  
The register set of the TTCAN can be accessed directly by an external CPU via the module  
interface. These registers are used to control/configure the CAN_Core and the Message  
Handler and to access the single-ported Message RAM.  
The module interfaces delivered with the TTCAN IP module can easily be replaced by a  
customized module interface adapted to the needs of the user.  
The TTCAN implements the following features:  
Supports CAN protocol version 2.0 part A, B and TTCAN (ISO 11898-4)  
Bit rates up to 1 MBit/s  
32 Message Objects, each Message Object has its own Identifier Mask  
Programmable FIFO mode for Message Objects  
TTCAN protocol level 1 and level 2 completely in hardware  
Event synchronised time triggered communication implemented  
Programmable loop-back mode for self-test operation  
two 16-bit module interfaces to the AMBA APB bus from ARM  
16-bit non-multiplex TI TMS470 compatible module interface  
8-bit non-multiplex Motorola HC08 compatible module interface  
manual_funct_descr.fm  
BOSCH  
- 8/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
2.2 Block Diagram  
CAN_TX  
CAN_RX  
CAN_Core  
CAN-Message  
Clock  
Reset  
Control  
Message RAM  
(single ported)  
Address  
DataIN  
Message Handler  
Trigger Memory  
DataOUT  
Wait  
Interrupt  
Trigger  
SWT, EVT  
TMI  
TTCAN - Frame Synchronisation Entity  
TTCAN  
Figure 1: Block Diagram of the TTCAN  
CAN_Core  
CAN Protocol Controller and Rx/Tx Shift Register, handles all ISO 11898-1 protocol functions.  
Message Handler  
State Machine that controls the data transfer between the single ported Message RAM, the  
CAN_Core’s Rx/Tx Shift Register, and the CPU IFC Registers. It also handles acceptance  
filtering and the interrupt setting as programmed in the Control and Configuration Registers.  
Message RAM / CPU IFC Registers  
Single ported RAM, word-length = [CAN message & acceptance filter mask & control bits &  
status bits]. To ensure data consistency, all CPU accesses to the Message RAM are relayed  
through CPU IFC registers that have the same word-length as the Message RAM.  
Frame Synchronisation Entity / Trigger Memory  
State machine that controls the ISO 11898-4 time triggered communication. It synchronises  
itself to the reference messages on the CAN bus, controls Cycle Time and Global Time, and  
handles transmissions according to the predefined message schedule, the system matrix.  
StopWatch Trigger, EVent Trigger, and Time Mark Interrupt are synchronisation interfaces.  
The Trigger Memory stores the time marks of the system matrix that are linked to the  
messages in the Message RAM.  
Module Interface  
Up to now the TTCAN module is provided with three different interfaces. An 8-bit interface for  
the Motorola HC08 controller a 16-bit interface to the TI TMS470 controller, and two 16-bit  
interfaces to the AMBA APB bus from ARM. They can easily be replaced by a user-defined  
module interface.  
BOSCH  
- 9/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
2.3 Operating Modes  
2.3.1 Software Initialisation  
The software initialization is started by setting the bit Init in the CAN Control Register, either  
by software or by a hardware reset, or by going Bus_Off.  
While Init is set, all message transfer from and to the CAN bus is stopped, the status of the  
CAN bus output CAN_TX is recessive (HIGH). The counters of the EML are unchanged.  
Setting Init does not change any configuration register.  
To initialize the CAN Controller, the CPU has to set up the Bit Timing Register and each  
Message Object. If a Message Object is not needed, it is sufficient to set it’s MsgVal bit to not  
valid. Otherwise, the whole Message Object has to be initialized.  
Access to the Bit Timing Register and to the BRP Extension Register for the configuration of  
the bit timing and to the TT Operation Mode Register for the configuration of the time triggered  
communication is enabled when both bits Init and CCE in the CAN Control Register are set.  
Resetting Init (by CPU only) finishes the software initialisation. Afterwards the Bit Stream  
Processor BSP (see section 4.2.1 on page 45) synchronizes itself to the data transfer on the  
CAN bus by waiting for the occurrence of a sequence of 11 consecutive recessive bits (Bus  
Idle) before it can take part in bus activities and starts the message transfer.  
The initialization of the Message Objects is independent of Init and can be done anytime, but  
the Message Objects should all be configured to particular identifiers or set to not valid before  
the BSP starts the message transfer.  
To change the configuration of a Message Object during normal operation, the CPU has to  
start by setting MsgVal to not valid. When the configuration is completed, MsgVal is set to  
valid again.  
To change the configuration of the time triggered communication, the TTMode in the  
TT Operation Mode Register must be set to Configuration Mode. Entering and leaving this  
Configuration Mode requires that both bits Init and CCE are set.  
2.3.2 CAN Message Transfer  
Once the TTCAN is initialized and Init is reset to zero, the TTCAN’s CAN_Core synchronizes  
itself to the CAN bus and starts the message transfer in the configured TTMode.  
Received messages are stored into their appropriate Message Objects if they pass the  
Message Handler’s acceptance filtering. The whole message including all arbitration bits, DLC  
and eight data bytes is stored into the Message Object. If the Identifier Mask is used, the  
arbitration bits which are masked to “don’t care” may be overwritten in the Message Object  
when a received message is stored.  
The CPU may read or write each message any time via the Interface Registers, the Message  
Handler guarantees data consistency in case of concurrent accesses.  
Messages to be transmitted are updated by the CPU. If a permanent Message Object  
(arbitration and control bits set up during configuration) exists for the message, only the data  
bytes are updated. How the transmission is started depends on the configured TTMode. If  
several transmit messages are assigned to the same Message Object (when the number of  
Message Objects is not sufficient), the whole Message Object has to be configured before the  
transmission of this message is requested.  
The transmission of any number of Message Objects may be requested at the same time, they  
are transmitted subsequently according to their internal priority. Messages may be updated or  
BOSCH  
- 10/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
set to not valid any time, even when their requested transmission is still pending. The old data  
will be discarded when a message is updated before its pending transmission has started.  
Depending on the configuration of the Message Object, the transmission of a message may  
be requested autonomously by the reception of a remote frame with a matching identifier.  
2.3.3 Disabled Automatic Retransmission  
According to the CAN Specification (see ISO11898, 6.3.3 Recovery Management), the  
TTCAN provides means for automatic retransmission of frames that have lost arbitration or  
that have been disturbed by errors during transmission. The frame transmission service will  
not be confirmed to the user before the transmission is successfully completed. By default,  
this means for automatic retransmission is enabled. It can be disabled to enable the TTCAN to  
work within a Time Triggered CAN (TTCAN, see ISO11898-1) environment.  
The Disabled Automatic Retransmission mode is enabled by programming bit DAR in the CAN  
Control Register to one. In this operation mode the programmer has to consider the different  
behaviour of bits TxRqst and NewDat in the Control Registers of the Message Buffers:  
When a transmission starts bit TxRqst of the respective Message Buffer is reset, while bit  
NewDat remains set.  
When the transmission completed successfully bit NewDat is reset.  
When a transmission failed (lost arbitration or error) bit NewDat remains set. To restart the  
transmission the CPU has to set TxRqst back to one.  
Note : It is not necessary to set DAR if the TTCAN is in time triggered operating mode.  
2.3.4 Test Mode  
The Test Mode is entered by setting bit Test in the CAN Control Register to one. In Test Mode  
the bits Tx1, Tx0, LBack, Silent, NoRAM, and WdOff in the Test Register are writable. Bit Rx  
monitors the state of pin CAN_RX and therefore is only readable. All Test Register functions  
are disabled when bit Test is reset to zero.  
Loop Back Mode, No Message RAM Mode, and CAN_TX Control Mode are hardware test  
modes, not to be used by application programs.  
Silent Mode and the Watchdog Disable Mode are software test modes.  
2.3.4.1 Test Register (addresses 0x0B & 0x0A)  
15  
14  
13  
res  
r
12  
res  
r
11  
res  
r
10  
res  
r
9
res  
r
8
res  
r
7
Rx  
r
6
5
4
3
2
1
0
StW EvT  
Tx1 Tx0 LBack Silent NoRAM res WdOff  
r
r
rw  
rw  
rw  
rw  
rw  
r
rw  
StW  
EvT  
Rx  
Monitors the actual value of the STOP_WATCH_TRIGGER pin  
Monitors the actual value of the EVENT_TRIGGER pin  
Monitors the actual value of the CAN_RX pin  
one  
zero  
The CAN bus is recessive (CAN_RX = ‘1’).  
The CAN bus is dominant (CAN_RX = ‘0’).  
Tx1-0  
Control of CAN_TX pin  
00  
01  
10  
11  
Reset value, CAN_TX is controlled by the CAN_Core.  
Sample Point can be monitored at CAN_TX pin.  
CAN_TX pin drives a dominant (‘0’) value.  
CAN_TX pin drives a recessive (‘1’) value.  
BOSCH  
- 11/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
LBack  
Loop Back Mode  
one  
zero  
Loop Back Mode is enabled.  
Loop Back Mode is disabled.  
Silent  
Silent Mode  
one  
zero  
The module is in Silent Mode  
Normal operation.  
NoRAM  
WdOff  
No Message RAM Mode  
one  
zero  
IF1 Registers used as Tx Buffer, IF2 Registers used as Rx Buffer.  
No Message RAM Mode disabled, normal Message RAM usage.  
Disable Watchdog  
one  
zero  
The Watchdog disabled.  
The Watchdog is enabled, after Initialization has finished (Init = 0).  
Write access to the Test Register is enabled by setting bit Test in the CAN Control Register.  
The different test functions may be combined, but Tx1-0 “00” disturbs message transfer.  
2.3.4.2 Disable Watchdog Mode  
The TT Application Watchdog (see chapter 3.5.6) can be disabled by programming the Test  
Register bit WdOff to one and the Application_Watchdog_Limit AppWdL to 0x00. When bit  
Test in the CAN Control Register is reset, WdOff is also reset if the TTCAN is in time triggered  
operating mode; if the TTCAN is in event driven CAN mode, WdOff is remains set and the TT  
Application Watchdog remains disabled (emulating the C_CAN function).  
The TT Application Watchdog should not be disabled in a TTCAN application program.  
2.3.4.3 Silent Mode  
The CAN_Core can be set in Silent Mode by programming the Test Register bit Silent to one.  
In Silent Mode, the TTCAN is able to receive valid data frames and valid remote frames, but it  
sends only recessive bits on the CAN bus and it cannot start a transmission. If the CAN_Core  
is required to send a dominant bit (ACK bit, overload flag, active error flag), the bit is rerouted  
internally so that the CAN_Core monitors this dominant bit, although the CAN bus may remain  
in recessive state. The Silent Mode can be used to analyse the traffic on a CAN bus without  
affecting it by the transmission of dominant bits (Acknowledge Bits, Error Frames). Figure 2  
shows the connection of signals CAN_TX and CAN_RX to the CAN_Core in Silent Mode.  
CAN_TX CAN_RX  
TTCAN  
=1  
Rx  
Tx  
CAN_Core  
Figure 2: CAN_Core in Silent Mode  
In ISO 11898-1, the Silent Mode is called the Bus Monitoring Mode.  
BOSCH  
- 12/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
2.3.4.4 Loop Back Mode  
The CAN_Core can be set in Loop Back Mode by programming the Test Register bit LBack to  
one. In Loop Back Mode, the CAN_Core treats its own transmitted messages as received  
messages and stores them (if they pass acceptance filtering) into a Receive Buffer. Figure 3  
shows the connection of signals CAN_TX and CAN_RX to the CAN_Core in Loop Back Mode.  
CAN_TX CAN_RX  
TTCAN  
Rx  
Tx  
CAN_Core  
Figure 3: CAN_Core in Loop Back Mode  
This mode is provided for hardware self-test functions. To be independent from external  
stimulation, the CAN_Core ignores acknowledge errors (recessive bit sampled in the  
acknowledge slot of a data/remote frame) in Loop Back Mode. In this mode the CAN_Core  
performs an internal feedback from its Tx output to its Rx input. The actual value of the  
CAN_RX input pin is disregarded by the CAN_Core. The transmitted messages can be  
monitored at the CAN_TX pin.  
2.3.4.5 Loop Back combined with Silent Mode  
It is also possible to combine Loop Back Mode and Silent Mode by programming bits LBack  
and Silent to one at the same time. This mode can be used for a “Hot Selftest”, meaning the  
TTCAN hardware can be tested without affecting a running CAN system connected to the pins  
CAN_TX and CAN_RX. In this mode the CAN_RX pin is disconnected from the CAN_Core  
and the CAN_TX pin is held recessive. Figure 4 shows the connection of signals CAN_TX and  
CAN_TX CAN_RX  
TTCAN  
=1  
Rx  
Tx  
CAN_Core  
Figure 4: CAN_Core in Loop Back combined with Silent Mode  
BOSCH  
- 13/77 -  
11.11.02  
 
       
User’s Manual  
2.3.4.6 Software control of Pin CAN_TX  
TTCAN  
Revision 1.6  
Four output functions are available for the CAN transmit pin CAN_TX. Additionally to its  
default function – the serial data output – it can drive the CAN Sample Point signal to monitor  
the CAN_Core’s bit timing and it can drive constant dominant or recessive values. The last two  
functions, combined with the readable CAN receive pin CAN_RX, can be used to check the  
CAN bus’ physical layer.  
The output mode of pin CAN_TX is selected by programming the Test Register bits Tx1 and  
The three test functions for pin CAN_TX interfere with all CAN protocol functions. CAN_TX  
must be left in its default function when CAN message transfer or any of the test modes Loop  
Back Mode, Silent Mode, or No Message RAM Mode are selected.  
2.3.4.7 No Message RAM Mode  
The CAN_Core can be set in No Message RAM Mode by programming the Test Register bit  
NoRAM to one. In this mode the TTCAN module operates without the Message RAM.  
The IF1 Registers are used as Transmit Buffer. The transmission of the contents of the IF1  
Registers is requested by writing the Busy bit of the IF1 Command Request Register to ‘1’.  
The IF1 Registers are locked while the Busy bit is set. The Busy bit indicates that the  
transmission is pending. The CPU-IFC’s output signal CAN_WAIT_B is disabled (always ‘1’)  
in this mode.  
As soon the CAN bus is idle, the IF1 Registers are loaded into the CAN_Core’s shift register  
and the transmission is started. When the transmission has completed, the Busy bit is reset  
and the locked IF1 Registers are released.  
A pending transmission can be aborted at any time by resetting the Busy bit in the IF1  
Command Request Register while the IF1 Registers are locked. If the CPU has reset the Busy  
bit, a possible retransmission in case of lost arbitration or in case of an error is disabled.  
The IF2 Registers are used as Receive Buffer. After the reception of a message the contents  
of the shift register is stored into the IF2 Registers, without any acceptance filtering.  
Additionally, the actual contents of the shift register can be monitored during the message  
transfer. Each time a read Message Object is initiated by writing the Busy bit of the IF2  
Command Request Register to ‘1’, the contents of the shift register is stored into the IF2  
Registers.  
In No Message RAM Mode the evaluation of all Message Object related control and status bits  
and of the control bits of the IFx Command Mask Registers is turned off. The message  
number of the Command request registers is not evaluated. The NewDat and MsgLst bits of  
the IF2 Message Control Register retain their function, DLC3-0 will show the received DLC,  
the other control bits will be read as ‘0’.  
The No Message RAM Mode is a hardware test mode that allows to evaluate the TTCAN IP  
RTL code in FPGA types that do not support the TTCAN’s Message RAM structure.  
BOSCH  
- 14/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
3. Programmer’s Model  
The TTCAN module allocates an address space of 256 bytes. The registers are organized as  
16-bit registers, with the high byte at the odd address and the low byte at the even address.  
The two sets of interface registers (IF1 and IF2) control the CPU access to the Message RAM.  
They buffer the data to be transferred to and from the RAM, avoiding conflicts between CPU  
accesses and message reception/transmission.  
Address  
Name  
Reset Value  
Note  
CAN Base+0x00  
CAN Base+0x02  
CAN Base+0x04  
CAN Base+0x06  
CAN Base+0x08  
CAN Base+0x0A  
CAN Base+0x0C  
CAN Base+0x0E  
CAN Base+0x10  
CAN Base+0x12  
CAN Base+0x14  
CAN Base+0x16  
CAN Base+0x18  
CAN Base+0x1A  
CAN Base+0x1C  
CAN Base+0x1E  
CAN Base+0x20  
CAN Base+0x22  
CAN Base+0x24  
CAN Base+0x26  
CAN Base+0x28  
CAN Base+0x2A  
CAN Base+0x2C  
CAN Base+0x2E  
CAN Base+0x30  
CAN Base+0x32  
CAN Base+0x34  
CAN Base+0x36  
CAN Base+0x38  
CAN Base+0x3A  
CAN Base+0x3C  
CAN Base+0x3E  
CAN Base+0x40  
CAN Base+0x42  
CAN Base+0x44  
CAN Base+0x46  
CAN Control Register  
Status Register  
Error Counter  
0x0001  
CAN config register  
CAN status register  
0x0000  
0x0000  
0x2301  
0x0000  
0x00 & 0b  
0x0000  
0x0000  
0x0001  
0x0000  
0xFFFF  
0xFFFF  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
CAN status register  
Bit Timing Register  
Interrupt Register  
Test Register  
CAN config reg., req. CCE  
CAN status register  
0000000 1) CAN appl. reg., req. Test  
CAN config reg., req. CCE  
TTCAN config register  
r
BRP Extension Register  
Trigger Memory Access  
IF1 Command Request  
IF1 Command Mask  
IF1 Mask 1  
CAN appl. IF1 Register Set  
IF1 Mask 2  
IF1 Arbitration 1  
IF1 Arbitration2  
IF1 Message Control  
IF1 Data A 1  
IF1 Data A 2  
IF1 Data B 1  
IF1 Data B 2  
2)  
— reserved  
TT Operation Mode  
TT Matrix Limits1  
TT Matrix Limits2  
0x0000  
0x0000  
0x0000  
TTCAN config register  
TTCAN config register  
TTCAN config register  
TTCAN config register  
TTCAN appl. register  
TTCAN status register  
TTCAN status register  
TTCAN status register  
TTCAN status register  
TTCAN status register  
TTCAN status register  
TTCAN status register  
CAN appl. IF2 Register Set  
TT Application Watchdog 0x0001  
TT Interrupt Enable  
TT Interrupt Vector  
TT Global Time  
TT Cycle Time  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x003F  
0x0000  
0x0001  
0x0000  
0xFFFF  
0xFFFF  
TT Local Time  
TT Master State  
TT Cycle Count  
TT Error Level  
IF2 Command Request  
IF2 Command Mask  
IF2 Mask 1  
IF2 Mask 2  
1) r signifies the actual value of the CAN_RX pin.  
2) Reserved bits are read as ’0’ except for IFx Mask 2 Register where they are read as ’1’  
BOSCH  
- 15/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
Address  
Name  
Reset Value  
Note  
CAN Base+0x48  
CAN Base+0x4A  
CAN Base+0x4C  
CAN Base+0x4E  
CAN Base+0x50  
CAN Base+0x52  
CAN Base+0x54  
CAN Base+0x56  
CAN Base+0x58  
CAN Base+0x5A  
CAN Base+0x5C  
CAN Base+0x5E  
CAN Base+0x60  
CAN Base+0x62  
CAN Base+0x64  
CAN Base+0x66  
CAN Base+0x68  
CAN Base+0x6A  
CAN Base+0x6C  
CAN Base+0x6E  
CAN Base+0x70-0x7E  
CAN Base+0x80  
CAN Base+0x82  
CAN Base+0x84-0x8E  
CAN Base+0x90  
CAN Base+0x92  
CAN Base+0x94-0x9E  
CAN Base+0xA0  
CAN Base+0xA2  
IF2 Arbitration 1  
IF2 Arbitration 2  
IF2 Message Control  
IF2 Data A 1  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x0000  
0x1000  
0x0000  
0x0001  
CAN appl. IF2 Register Set  
IF2 Data A 2  
IF2 Data B 1  
IF2 Data B 2  
TUR-NumeratorCfg  
TUR-DenominatorCfg  
TUR-NumeratorActL  
TUR-NumeratorActH  
— reserved  
TTCAN config register  
TTCAN config register  
TTCAN status register  
TTCAN status register  
2)  
Stop_Watch  
0x0000  
TTCAN status register  
2)  
— reserved  
Global Time Preset  
Clock Control  
0x0000  
0x1000  
0x0000  
TTCAN appl. register  
TTCAN appl. register  
TTCAN status register  
Sync_Mark  
2)  
— reserved  
Time Mark  
0x0000  
0x0000  
TTCAN appl. register  
TTCAN appl. register  
Gap Control  
2)  
— reserved  
Transmission Request 1  
Transmission Request 2  
— reserved  
0x0000  
0x0000  
CAN status register  
CAN status register  
2)  
New Data 1  
0x0000  
0x0000  
CAN status register  
CAN status register  
New Data 2  
2)  
— reserved  
Interrupt Pending 1  
Interrupt Pending 2  
0x0000  
0x0000  
CAN status register  
CAN status register  
2)  
CAN Base+0xA4-0xAE — reserved  
CAN Base+0xB0  
CAN Base+0xB2  
Message Valid 1  
Message Valid 2  
0x0000  
0x0000  
CAN status register  
CAN status register  
2)  
CAN Base+0xB4-0xBE — reserved  
1) r signifies the actual value of the CAN_RX pin.  
2) Reserved bits are read as ’0’ except for IFx Mask 2 Register where they are read as ’1’  
Figure 5: TTCAN Register Summary  
3.1 Hardware Reset Description  
After hardware reset, the registers of the TTCAN hold the values described in figure 5.  
Additionally the Bus_Off state is reset and the output CAN_TX is set to recessive (HIGH). The  
value 0x0001 (Init = ‘1’) in the CAN Control Register enables the software initialisation. The  
TTCAN does not influence the CAN bus until the CPU resets Init to ‘0’.  
The data in the Message RAM is (apart from the MsgVal, NewDat, TxRqst, and IntPnd bits)  
not affected by a hardware reset. After power-on, the contents of the Message RAM is undefined.  
BOSCH  
- 16/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
3.2 CAN Protocol Related Registers  
These registers are related to the CAN protocol controller in the CAN Core. They control the  
operating modes and the configuration of the CAN bit timing and provide status information.  
3.2.1 CAN Control Register (addresses 0x01 & 0x00)  
15  
res  
r
14  
res  
r
13  
res  
r
12  
res  
r
11  
res  
r
10  
res  
r
9
res  
r
8
res  
r
7
6
5
4
3
2
1
0
Test CCE DAR res  
rw rw rw  
EIE SIE  
rw rw  
IE  
rw  
Init  
rw  
r
Test  
CCE  
DAR  
EIE  
Test Mode Enable  
one  
zero  
Test Mode.  
Normal Operation.  
Configuration Change Enable  
one  
The CPU has write access to the configuration registers (while Init = one).  
zero  
The CPU has no write access to the configuration registers.  
Disable Automatic Retransmission  
one  
Automatic Retransmission disabled.  
zero  
Automatic Retransmission of not successful messages enabled.  
Error Interrupt Enable  
one  
Enabled - A change in the bits BOff or EWarn in the Status Register will  
generate an interrupt.  
zero  
Disabled - No Error Status Interrupt will be generated.  
SIE  
IE  
Status Change Interrupt Enable  
one  
Enabled - An interrupt will be generated when a message transfer is suc-  
cessfully completed or a CAN bus error is detected.  
zero  
Disabled - No Status Change Interrupt will be generated.  
Module Interrupt Enable  
one  
Enabled - Interrupts will set IRQ_B to LOW. IRQ_B remains LOW until all  
pending interrupts are processed.  
zero  
Disabled - Module Interrupt IRQ_B is always HIGH.  
Init  
Initialization  
one  
zero  
Initialization is started.  
Normal Operation.  
The configuration registers controlled by CCE are the Bit Timing Register, the BRP Extension  
Register, and the TT Operation Mode Register.  
Note : The Bus_Off recovery sequence (see CAN Specification Rev. 2.0) cannot be shortened by set-  
ting or resetting Init. If the device goes Bus_Off, it will set Init of its own accord, stopping all bus  
activities. Once Init has been cleared by the CPU, the device will then wait for 129 occurrences  
of Bus Idle (129 * 11 consecutive recessive bits) before resuming normal operations. At the end  
of the Bus_Off recovery sequence, the Error Management Counters will be reset.  
During the waiting time after the resetting of Init, each time a sequence of 11 recessive bits  
has been monitored, a Bit0Error code is written to the Status Register, enabling the CPU to  
readily check up whether the CAN bus is stuck at dominant or continuously disturbed and to  
monitor the proceeding of the Bus_Off recovery sequence.  
BOSCH  
- 17/77 -  
11.11.02  
 
   
User’s Manual  
3.2.2 Status Register (addresses 0x03 & 0x02)  
TTCAN  
Revision 1.6  
15  
res  
r
14  
res  
r
13  
res  
r
12  
res  
r
11  
res  
r
10  
res  
r
9
res  
r
8
7
6
EWarn  
r
5
4
3
2
1
LEC  
rw  
0
res BOff  
EPass RxOk TxOk  
rw rw  
r
r
r
BOff  
Bus_Off Status  
one The CAN module is in Bus_Off state.  
zero The CAN module is not Bus_Off.  
EWarn Warning Status  
one At least one of the error counters in the EML has reached the error warning  
limit of 96.  
zero Both error counters are below the error warning limit of 96.  
EPass Error Passive  
one The CAN Core is in the error passive state as defined in the CAN Specification.  
zero The CAN Core is error active.  
RxOk Received a Message Successfully  
one Since this bit was last reset (to zero) by the CPU, a message has been suc-  
cessfully received (independent of the result of acceptance filtering).  
zero Since this bit was last reset by the CPU, no message has been successfully  
received. This bit is never reset by the CAN Core.  
TxOk Transmitted a Message Successfully  
one Since this bit was last reset by the CPU, a message has been successfully  
(error free and acknowledged by at least one other node) transmitted.  
zero Since this bit was reset by the CPU, no message has been successfully trans-  
mitted. This bit is never reset by the CAN Core.  
LEC  
Last Error Code (Type of the last error to occur on the CAN bus)  
0
1
No Error  
Stuff Error : More than 5 equal bits in a sequence have occurred in a part of a  
received message where this is not allowed.  
2
3
Form Error : A fixed format part of a received frame has the wrong format.  
AckError : The message this CAN Core transmitted was not acknowledged by  
another node.  
4
5
Bit1Error : During the transmission of a message (with the exception of the  
arbitration field), the device wanted to send a recessive level (bit of logical value  
‘1’), but the monitored bus value was dominant.  
Bit0Error : During the transmission of a message (or acknowledge bit, or  
active error flag, or overload flag), the device wanted to send a dominant level  
(data or identifier bit logical value ‘0’), but the monitored bus value was reces-  
sive. During Bus_Off recovery this status is set each time a sequence of 11  
recessive bits has been monitored. This enables the CPU to monitor the pro-  
ceeding of the Bus_Off recovery sequence (indicating the bus is not stuck at  
dominant or continuously disturbed).  
6
7
CRCError : The CRC check sum was incorrect in the message received, the  
CRC received for an incoming message does not match with the calculated  
CRC for the received data.  
unused : When the LEC shows the value ‘7’, no CAN bus event was detected  
since the CPU wrote this value to the LEC.  
BOSCH  
- 18/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
The LEC field holds a code which indicates the type of the last error to occur on the CAN bus.  
This field will be cleared to ‘0’ when a message has been transferred (reception or transmis-  
sion) without error. The unused code ‘7’ may be written by the CPU to check for updates.  
3.2.2.1 Status Interrupts  
A Status Interrupt is generated by bits BOff and EWarn (Error Interrupt, EIE) or by RxOk,  
TxOk, and LEC (Status Change Interrupt, SIE) assumed that the corresponding enable bits in  
the CAN Control Register are set. A change of bit EPass or a CPU write to RxOk, TxOk, or  
LEC will never generate a Status Interrupt.  
When SIE is set, a Status Interrupt will be generated at each CAN bus error and at each valid  
CAN message, independent of the Message RAM configuration.  
Reading the Status Register will clear the Status Interrupt value (8000h) in the Interrupt  
Register, if it is pending.  
3.2.3 Error Counter (addresses 0x05 & 0x04)  
15  
RP  
r
14  
13  
12  
11  
REC6-0  
r
10  
9
8
7
6
5
4
3
2
1
0
TEC7-0  
r
RP  
Receive Error Passive  
one  
The Receive Error Counter has reached the error passive level as defined  
in the CAN Specification.  
zero  
The Receive Error Counter is below the error passive level.  
REC6-0  
TEC7-0  
Receive Error Counter  
Actual state of the Receive Error Counter. Values between 0 and 127.  
Transmit Error Counter  
Actual state of the Transmit Error Counter. Values between 0 and 255.  
3.2.4 Bit Timing Register (addresses 0x07 & 0x06)  
15  
res  
r
14  
13  
TSeg2  
rw  
12  
11  
10  
TSeg1  
rw  
9
8
7
6
5
4
3
2
1
0
SJW  
BRP  
rw  
rw  
TSeg1  
TSeg2  
SJW  
The time segment before the sample point  
0x01-0x0F  
valid values for TSeg1 are [1 … 15]. The actual interpretation by  
the hardware of this value is such that one more than the value  
programmed here is used.  
The time segment after the sample point  
0x0-0x7 valid values for TSeg2 are [0 … 7]. The actual interpretation by  
the hardware of this value is such that one more than the value  
programmed here is used.  
(Re)Synchronisation Jump Width  
0x0-0x3 Valid programmed values are 0-3. The actual interpretation by  
the hardware of this value is such that one more than the value  
programmed here is used.  
BOSCH  
- 19/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
BRP  
Baud Rate Prescaler  
0x00-0x3F  
The value by which the oscillator frequency is divided for gener-  
ating the bit time quanta. The bit time is built up from a multiple  
of this quanta. Valid values for the Baud Rate Prescaler are  
[0 … 63]. The actual interpretation by the hardware of this value  
is such that one more than the value programmed here is used.  
This register is only writable if bits CCE and Init in the CAN Control Register are set. The CAN  
bit time may be programed in the range of [4 … 25] time quanta. The CAN time quantum may  
be programmed in the range of [1 … 1024] CAN_CLK periods. For details see chapter 4.2.1.  
Note : With a module clock CAN_CLK of 8 MHz and BRPE = 0x00, the reset value of 0x2301 config-  
ures the TTCAN for a bit rate of 500 kBit/s.  
3.2.5 BRP Extension Register (addresses 0x0D & 0x0C)  
15  
res  
r
14  
res  
r
13  
res  
r
12  
res  
r
11  
res  
r
10  
res  
r
9
res  
r
8
res  
r
7
res  
r
6
res  
r
5
res  
r
4
res  
r
3
2
1
0
BRPE  
rw  
BRPE  
Baud Rate Prescaler Extension  
0x00-0x0F  
By programming BRPE the Baud Rate Prescaler can be  
extended to values up to 1023. The actual interpretation by the  
hardware is that one more than the value programmed by BRPE  
(MSBs) and BRP (LSBs) is used.  
This register is only writable if bits CCE and Init in the CAN Control Register are set.  
Note : The width of BRPE may be increased to more than its default width of 4 bits in particular imple-  
mentations of the TTCAN IP module width a high module clock frequency.  
3.3 Message Interface Register Sets  
Address  
IF1 Register Set  
Address  
IF2 Register Set  
CAN Base+0x10  
CAN Base+0x12  
CAN Base+0x14  
CAN Base+0x16  
CAN Base+0x18  
CAN Base+0x1A  
CAN Base+0x1C  
CAN Base+0x1E  
CAN Base+0x20  
CAN Base+0x22  
CAN Base+0x24  
IF1 Command Request  
IF1 Command Mask  
IF1 Mask 1  
CAN Base+0x40  
CAN Base+0x42  
CAN Base+0x44  
CAN Base+0x46  
CAN Base+0x48  
CAN Base+0x4A  
CAN Base+0x4C  
CAN Base+0x4E  
CAN Base+0x50  
CAN Base+0x52  
CAN Base+0x54  
IF2 Command Request  
IF2 Command Mask  
IF2 Mask 1  
IF1 Mask 2  
IF2 Mask 2  
IF1 Arbitration 1  
IF1 Arbitration 2  
IF1 Message Control  
IF1 Data A 1  
IF2 Arbitration 1  
IF2 Arbitration 2  
IF2 Message Control  
IF2 Data A 1  
IF1 Data A 2  
IF2 Data A 2  
IF1 Data B 1  
IF2 Data B 1  
IF1 Data B 2  
IF2 Data B 2  
Figure 6: IF1 and IF2 Message Interface Register Sets  
There are two sets of Interface Registers that control the CPU access to the Message RAM.  
The Interface Registers avoid (by buffering the data to be transferred) conflicts between CPU  
access to the Message RAM and CAN message reception and transmission. A complete  
Message Object (see chapter 3.3.4) or parts of the Message Object may be transferred  
between the Message RAM and the IFx Message Buffer registers (see chapter 3.3.3) in one  
BOSCH  
- 20/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
single transfer. This transfer, performed in parallel on all selected parts of the Message Object,  
guarantees the data consistency of the CAN message. Figure 6 shows the structure of the two  
Interface Register sets.  
The function of the two Interface Register sets is identical (except for test mode NoRAM). The  
second interface register set is provided to serve application programming. Two groups of  
software drivers may defined, each group is restricted to the use of one of the Interface  
Register sets. The software drivers of one group may interrupt software drivers of the other  
group, but not of the same group.  
In a simple example, there is one Read_Message task that uses IFC1 to get received  
messages from the Message RAM and there is one Write_Message task that uses IFC2 to  
write messages to be transmitted into the Message RAM. Both tasks may interrupt each other.  
Each set of Interface Registers consists of Message Buffer Registers controlled by their own  
Command Registers. The Command Mask Register specifies the direction of the data transfer  
and which parts of a Message Object will be transferred. The Command Request Register is  
used to select a Message Object in the Message RAM as target or source for the transfer and  
to start the action specified in the Command Mask Register.  
3.3.1 IFx Command Mask Registers  
The control bits of the IFx Command Mask Register specify the transfer direction and select  
which of the IFx Message Buffer Registers are source or target of the data transfer.  
15 14 13 12 11 10 9 8  
7
6
5
4
3
2
1
0
IF1 Command Mask Register  
(addresses 0x13 & 0x12)  
TxRqst/  
NewDat  
ClrIntPnd  
res  
WR/RD Mask Arb Control  
WR/RD Mask Arb Control  
Data A Data B  
Data A Data B  
IF2 Command Mask Register  
(addresses 0x43 & 0x42)  
TxRqst/  
NewDat  
ClrIntPnd  
res  
r
r
r
r
r
r r r  
rw  
rw rw  
rw  
rw  
rw  
rw  
rw  
WR/RD  
Write / Read  
one  
Write: Transfer data from the selected Message Buffer Registers to the  
Message Object addressed by the Command Request Register.  
Read: Transfer data from the Message Object addressed by the Com-  
mand Request Register into the selected Message Buffer Registers.  
zero  
The other bits of IFx Command Mask Register have different functions depending on the  
transfer direction :  
3.3.1.1 Direction = Write  
Mask  
Access Mask Bits  
one  
zero  
transfer Identifier Mask + MDir + MXtd to Message Object.  
Mask bits unchanged.  
Arb  
Access Arbitration Bits  
one  
zero  
transfer Identifier + Dir + Xtd + MsgVal to Message Object.  
Arbitration bits unchanged.  
Control  
Access Control Bits  
one  
zero  
transfer Control Bits to Message Object.  
Control Bits unchanged.  
Note : MSC2-0 is read-only in time triggered operating mode.  
BOSCH  
- 21/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
ClrIntPnd Clear Interrupt Pending Bit  
Note : When writing to a Message Object, this bit is ignored.  
TxRqst/NewDatAccess Transmission Request Bit  
one  
set TxRqst bit  
zero  
TxRqst bit unchanged  
Note : If a transmission is requested by setting TxRqst/NewDat in the IFx Command Mask Register,  
bit TxRqst in the IFx Message Control Register will be ignored.  
Data A  
Access Data Bytes 0-3  
one  
zero  
transfer Data Bytes 0-3 to Message Object.  
Data Bytes 0-3 unchanged.  
Data B  
Access Data Bytes 4-7  
one  
zero  
transfer Data Bytes 4-7 to Message Object.  
Data Bytes 4-7 unchanged.  
3.3.1.2 Direction = Read  
Mask  
Access Mask Bits  
one  
zero  
transfer Identifier Mask + MDir + MXtd to IFx Message Buffer Register.  
Mask bits unchanged.  
Arb  
Access Arbitration Bits  
one  
zero  
transfer Identifier + Dir + Xtd + MsgVal to IFx Message Buffer Register.  
Arbitration bits unchanged.  
Control  
Access Control Bits  
one  
zero  
transfer Control Bits to IFx Message Buffer Register.  
Control Bits unchanged.  
ClrIntPnd Clear Interrupt Pending Bit  
one  
zero  
clear IntPnd bit in the Message Object.  
IntPnd bit remains unchanged.  
TxRqst/NewDatAccess New Data Bit  
one  
zero  
clear NewDat bit in the Message Object.  
NewDat bit remains unchanged.  
Note : A read access to a Message Object can be combined with the reset of the control bits IntPnd  
and NewDat. The values of these bits transferred to the IFx Message Control Register always  
reflect the status before resetting them.  
Data A  
Access Data Bytes 0-3  
one  
zero  
transfer Data Bytes 0-3 to IFx Message Buffer Register.  
Data Bytes 0-3 unchanged.  
Data B  
Access Data Bytes 4-7  
one  
zero  
transfer Data Bytes 4-7 to IFx Message Buffer Register.  
Data Bytes 4-7 unchanged.  
Note : The speed of the message transfer does not depend on how many bytes are transferred.  
3.3.2 IFx Command Request Registers  
A message transfer is started as soon as the CPU has written the message number to low  
byte of the Command Request Register. With this write operation, the Busy bit is  
automatically set to ‘1’ to notify the CPU that a transfer is in progress. After a wait time of 3 to  
BOSCH  
- 22/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
6 CAN_CLK periods, the transfer between the Interface Register and the Message RAM has  
completed and the Busy bit is cleared to ‘0’. The upper limit of the wait time occurs when the  
message transfer coincides with a CAN message transmission, acceptance filtering, or  
message storage. If the CPU-IFC is implemented with the wait-function, the CPU is halted  
while the Busy bit is set. If the CPU writes to both Command Request Registers consecutively  
(requests a second transfer while another transfer is already in progress), the second transfer  
starts when the first one is completed.  
IF1 Command Request Register  
(addresses 0x11 & 0x10)  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
Busy  
res  
res  
r
res  
res  
r
Message Number  
Message Number  
rw  
IF2 Command Request Register Busy  
(addresses 0x41 & 0x40)  
r
Busy  
Busy Flag  
one  
zero  
set to one when writing to the IFx Command Request Register  
reset to zero when read/write action has finished.  
Message Number  
0x01-0x20  
Valid Message Number, the Message Object in the Message  
RAM is selected for data transfer.  
0x00  
0x21-0x3F  
Not a valid Message Number, interpreted as 0x20.  
Not a valid Message Number, interpreted as 0x01-0x1F.  
Note : When an invalid Message Number is written to the Command Request Register, the Message  
Number will be transformed into a valid value and that Message Object will be transferred.  
3.3.3 IFx Message Buffer Registers  
The bits of the Message Buffer registers mirror the Message Objects in the Message RAM.  
The function of the Message Objects bits is described in chapter 3.3.4.  
3.3.3.1 IFx Mask Registers  
IF1 Mask 1 Register  
15  
14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
(addresses 0x15 & 0x14)  
Msk15-0  
IF1 Mask 2 Register  
(addresses 0x17 & 0x16)  
MXtd MDir res  
Msk28-16  
IF2 Mask 1 Register  
(addresses 0x45 & 0x44)  
Msk15-0  
IF2 Mask 2 Register  
MXtd MDir res  
Msk28-16  
(addresses 0x47 & 0x46)  
rw  
rw  
r
rw  
3.3.3.2 IFx Arbitration Registers  
IF1 Arbitration 1 Register  
(addresses 0x19 & 0x18)  
15  
14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
ID15-0  
IF1 Arbitration 2 Register  
(addresses 0x1B& 0x1A)  
MsgVal Xtd Dir  
ID28-16  
IF2 Arbitration 1 Register  
(addresses 0x49 & 0x48)  
ID15-0  
IF2 Arbitration 2 Register  
(addresses 0x4B & 0x4A)  
MsgVal Xtd Dir  
rw rw rw  
ID28-16  
rw  
BOSCH  
- 23/77 -  
11.11.02  
 
     
User’s Manual  
3.3.3.3 IFx Message Control Registers  
TTCAN  
Revision 1.6  
IF1 Message Control Register  
(addresses 0x1D & 0x1C)  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4 3 2 1 0  
NewDat MsgLst IntPnd UMask TxIE RxIE RmtEn TxRqst EoB MSC2-0 DLC3-0  
IF2 Message Control Register NewDat MsgLst IntPnd UMask TxIE RxIE RmtEn TxRqst EoB MSC2-0 DLC3-0  
(addresses 0x4D & 0x4C)  
rw  
rw  
rw  
rw  
rw rw  
rw  
rw  
rw  
rw  
rw  
3.3.3.4 IFx Data A and Data B Registers  
The data bytes of CAN messages are stored in the IFx registers in the following order:  
15 14 13 12 11 10  
Data(1)  
9
8
7
6
5
4
3
2
1
0
IF1 Message Data A1 (addresses 0x1F & 0x1E)  
IF1 Message Data A2 (addresses 0x21 & 0x20)  
IF1 Message Data B1 (addresses 0x23 & 0x22)  
IF1 Message Data B2 (addresses 0x25 & 0x24)  
IF2 Message Data A1 (addresses 0x4F & 0x4E)  
IF2 Message Data A2 (addresses 0x51 & 0x50)  
IF2 Message Data B1 (addresses 0x53 & 0x52)  
IF2 Message Data B2 (addresses 0x55 & 0x54)  
Data(0)  
Data(2)  
Data(4)  
Data(6)  
Data(0)  
Data(2)  
Data(4)  
Data(6)  
rw  
Data(3)  
Data(5)  
Data(7)  
Data(1)  
Data(3)  
Data(5)  
Data(7)  
rw  
In a CAN Data Frame, Data(0) is the first, Data(7) is the last byte to be transmitted or received.  
In CAN’s serial bit stream, the MSB of each byte will be transmitted first.  
3.3.4 Message Object in the Message Memory  
There are 32 Message Objects in the Message RAM. To avoid conflicts between CPU access  
to the Message RAM and CAN message reception and transmission, the CPU cannot directly  
access the Message Objects, these accesses are handled via the IFx Interface Registers.  
Figure 7 gives an overview of the two structure of a Message Object.  
Message Object  
UMask Msk28-0 MXtd MDir  
EoB MSC2-0 NewDat MsgLst RxIE TxIE IntPnd RmtEn TxRqst  
MsgVal ID28-0 Xtd Dir DLC3-0 Data 0 Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7  
Figure 7: Structure of a Message Object in the Message Memory  
MsgVal Message Valid  
one  
The Message Object is configured and should be considered by the Mes-  
sage Handler.  
zero  
The Message Object is ignored by the Message Handler.  
Note : The CPU must reset the MsgVal bit of all unused Messages Objects during the initialization  
before it resets bit Init in the CAN Control Register. This bit must also be reset before the iden-  
tifier Id28-0, the control bits Xtd, Dir, or the Data Length Code DLC3-0 are modified, or if the  
Messages Object is no longer required.  
UMask  
Use Acceptance Mask  
one  
zero  
Use Mask (Msk28-0, MXtd, and MDir) for acceptance filtering  
Mask ignored.  
Note : If the UMask bit is set to one, the Message Object’s mask bits have to be programmed during  
initialization of the Message Object before MsgVal is set to one.  
BOSCH  
- 24/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
ID28-0  
Message Identifier  
ID28 - ID0  
ID28 - ID18  
29-bit Identifier (“Extended Frame”).  
11-bit Identifier (“Standard Frame”).  
Msk28-0 Identifier Mask  
one  
zero  
The corresponding identifier bit is used for acceptance filtering.  
The corresponding bit in the identifier of the message object cannot inhibit  
the match in the acceptance filtering.  
Xtd  
Extended Identifier  
one  
zero  
The 29-bit (“extended”) Identifier will be used for this Message Object.  
The 11-bit (“standard”) Identifier will be used for this Message Object.  
MXtd  
Mask Extended Identifier  
one  
zero  
The extended identifier bit (IDE) is used for acceptance filtering.  
The extended identifier bit (IDE) has no effect on the acceptance filtering  
Note : When 11-bit (“standard”) Identifiers are used for a Message Object, the identifiers of received  
Data Frames are written into bits ID28 to ID18. For acceptance filtering, only these bits together  
with mask bits Msk28 to Msk18 are considered.  
Dir  
Message Direction  
one  
Direction = transmit: On TxRqst, the respective Message Object is trans-  
mitted as a Data Frame. On reception of a Remote Frame with matching  
identifier, the TxRqst bit of this Message Object is set (if RmtEn = one).  
Direction = receive: On TxRqst, a Remote Frame with the identifier of this  
Message Object is transmitted. On reception of a Data Frame with match-  
ing identifier, that message is stored in this Message Object.  
zero  
MDir  
Mask Message Direction  
one  
zero  
The message direction bit (Dir) is used for acceptance filtering.  
The message direction bit (Dir) has no effect on the acceptance filtering.  
The Arbitration Registers ID28-0, Xtd, and Dir are used to define the identifier and type of  
outgoing messages and are used (together with the mask registers Msk28-0, MXtd, and  
MDir) for acceptance filtering of incoming messages. A received message is stored into the  
valid Message Object with matching identifier and Direction=receive (Data Frame) or  
Direction=transmit (Remote Frame). Extended frames can be stored only in Message Objects  
with Xtd = one, standard frames in Message Objects with Xtd = zero. If a received message  
(Data Frame or Remote Frame) matches with more than one valid Message Object, it is stored  
into that with the lowest message number. For details see chapter 4.1.3 Acceptance Filtering  
EoB  
End of Block  
one  
Single Message Object or last Message Object of a FIFO Buffer Block.  
zero  
Message Object belongs to a FIFO Buffer Block and is not the last Mes-  
sage Object of that FIFO Buffer Block.  
Note : This bit is used to concatenate two ore more Message Objects (up to 32) to build a FIFO Buffer.  
For single Message Objects (not belonging to a FIFO Buffer) this bit must always be set  
MSC2-0  
Message Status Count  
0-7 The actual value of the Message Status Count, read-only in active mode.  
Note : The Message Status Count is status information that is generated for periodic Message Objects  
in Time Triggered Communication (ISO11898-4). It has no function in Event Driven CAN Com-  
munication (ISO11898-1) and for arbitrating Message Objects in TTCAN.  
BOSCH  
- 25/77 -  
11.11.02  
 
User’s Manual  
TTCAN  
Revision 1.6  
NewDat  
New Data  
one  
The Message Handler or the CPU has written new data into the data por-  
tion of this Message Object.  
zero  
No new data has been written into the data portion of this Message Object  
by the Message Handler since last time this flag was cleared by the CPU.  
MsgLst  
Message Lost (only valid for Message Objects with direction = receive)  
one  
The Message Handler stored a new message into this object when New-  
Dat was still set, the CPU has lost a message.  
zero  
No message lost since last time this bit was reset by the CPU.  
RxIE  
Receive Interrupt Enable  
one  
zero  
IntPnd will be set after a successful reception of a frame.  
IntPnd will be left unchanged after a successful reception of a frame.  
TxIE  
Transmit Interrupt Enable  
one  
zero  
IntPnd will be set after a successful transmission of a frame.  
IntPnd will be left unchanged after the successful transmission of a frame.  
IntPnd  
Interrupt Pending  
one  
This message object is the source of an interrupt. The Interrupt Identifier  
in the Interrupt Register will point to this message object if there is no  
other interrupt source with higher priority.  
zero  
This message object is not the source of an interrupt.  
RmtEn  
TxRqst  
Remote Enable  
one  
zero  
At the reception of a Remote Frame, TxRqst is set.  
At the reception of a Remote Frame, TxRqst is left unchanged.  
Transmit Request  
one  
zero  
The transmission of this Message Object is requested and is not yet done.  
This Message Object is not waiting for transmission.  
Note : In TTCAN mode, there are two types of transmit Message Objects. When NewDat is set and  
TxRqst is reset, the message will be transmitted periodically at each Transmit_Trigger for this  
message, without changing NewDat or TxRqst. When both NewDat and TxRqst are set, the  
message will be transmitted once at a Transmit_Trigger for this message, inside an arbitrating  
time window. When the transmission was not successful, it will be repeated at the next  
Transmit_Trigger for this message. When the transmission was successful, NewDat is reset.  
DLC3-0  
Data Length Code  
0-8  
9-15  
Data Frame has 0-8 data bytes.  
Data Frame has 8 data bytes  
Note : The Data Length Code of a Message Object must be defined the same as in all the correspond-  
ing objects with the same identifier at other nodes. When the Message Handler stores a data  
frame, it will write the DLC to the value given by the received message.  
BOSCH  
- 26/77 -  
11.11.02  
 
User’s Manual  
1st data byte of a CAN Data Frame  
TTCAN  
Revision 1.6  
Data 0  
Data 1  
Data 2  
Data 3  
Data 4  
Data 5  
Data 6  
Data 7  
2nd data byte of a CAN Data Frame  
3rd data byte of a CAN Data Frame  
4th data byte of a CAN Data Frame  
5th data byte of a CAN Data Frame  
6th data byte of a CAN Data Frame  
7th data byte of a CAN Data Frame  
8th data byte of a CAN Data Frame  
Note : Byte Data 0 is the first data byte shifted into the shift register of the CAN Core during a recep-  
tion, byte Data 7 is the last. When the Message Handler stores a Data Frame, it will write all the  
eight data bytes into a Message Object. If the Data Length Code is less than 8, the remaining  
bytes of the Message Object will be overwritten by non specified values.  
3.4 Message Handler Registers  
All Message Handler registers are read-only. Their contents (TxRqst, NewDat, IntPnd, and  
MsgVal bits of each Message Object and the Interrupt Identifier) is status information provided  
by the Message Handler FSM.  
3.4.1 Interrupt Register (addresses 0x09 & 0x08)  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
IntId15-8  
IntId7-0  
r
r
IntId15-0 Interrupt Identifier (the number here indicates the source of the interrupt)  
0x0000 No interrupt is pending.  
0x0001-0x0020 Number of Message Object which caused the interrupt.  
0x0021-0x3FFF unused.  
0x4000  
TTCAN Interrupt.  
0x4001-0x7FFF unused.  
0x8000  
Status Interrupt.  
0x8001-0xBFFF unused.  
0xC000  
TTCAN Interrupt and Status Interrupt.  
0xC001-0xFFFF unused.  
If several interrupts are pending, the CAN Interrupt Register will point to the pending interrupt  
with the highest priority, disregarding their chronological order. An interrupt remains pending  
until the CPU has cleared it. If IntId is different from 0x0000 and IE is set, the interrupt line to  
the CPU, IRQ_B, is active. The interrupt line remains active until IntId is back to value 0x0000  
(the cause of the interrupt is reset) or until IE is reset.  
The Status Interrupt has the highest priority. Among the message interrupts, the Message  
Object’s interrupt priority decreases with increasing message number.  
A message interrupt is cleared by clearing the Message Object’s IntPnd bit. The Status  
Interrupt is cleared by reading the Status Register. The TTCAN Interrupt is cleared by reading  
the TTCAN Interrupt Vector Register.  
BOSCH  
- 27/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
3.4.2 Transmission Request Registers  
Transmission Request 1 Register 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
(addresses 0x81 & 0x80)  
TxRqst16-9  
TxRqst8-1  
Transmission Request 2 Register  
(addresses 0x83 & 0x82)  
TxRqst32-25  
TxRqst24-17  
r
r
TxRqst32-1Transmission Request Bits (of all Message Objects)  
one  
zero  
The transmission of this Message Object is requested and is not yet done.  
This Message Object is not waiting for transmission.  
These registers hold the TxRqst bits of the 32 Message Objects. By reading out the TxRqst  
bits, the CPU can check for which Message Object a Transmission Request is pending. The  
TxRqst bit of a specific Message Object can be set/reset by the CPU via the IFx Message  
Interface Registers or (when not in time triggered mode) by the Message Handler after  
reception of a Remote Frame or after a successful transmission.  
3.4.3 New Data Registers  
New Data 1 Register  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
(addresses 0x91 & 0x90)  
NewDat16-9  
NewDat32-25  
r
NewDat8-1  
New Data 2 Register  
(addresses 0x93 & 0x92)  
NewDat24-17  
r
NewDat32-1New Data Bits (of all Message Objects)  
one  
The Message Handler or the CPU has written new data into the data por-  
tion of this Message Object.  
zero  
No new data has been written into the data portion of this Message Object  
by the Message Handler since last time this flag was cleared by the CPU.  
MsgLstThese registers hold the NewDat bits of the 32 Message Objects. By reading out the  
NewDat bits, the CPU can check for which Message Object the data portion was updated.  
The NewDat bit of a specific Message Object can be set/reset by the CPU via the IFx  
Message Interface Registers or by the Message Handler after reception of a Data Frame or  
after a successful transmission.  
3.4.4 Interrupt Pending Registers  
Interrupt Pending 1 Register  
(addresses 0xA1 & 0xA0)  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
IntPnd16-9  
IntPnd32-25  
r
IntPnd8-1  
IntPnd24-17  
r
Interrupt Pending 2 Register  
(addresses 0xA3 & 0xA2)  
IntPnd32-1 Interrupt Pending Bits (of all Message Objects)  
one  
zero  
This message object is the source of an interrupt.  
This message object is not the source of an interrupt.  
These registers hold the IntPnd bits of the 32 Message Objects. By reading out the IntPnd  
bits, the CPU can check for which Message Object an interrupt is pending. The IntPnd bit of a  
specific Message Object can be set/reset by the CPU via the IFx Message Interface Registers  
or by the Message Handler after reception or after a successful transmission of a frame. This  
will also affect the value of IntId in the Interrupt Register.  
BOSCH  
- 28/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
3.4.5 Message Valid 1 Register  
Message Valid 1 Register  
(addresses 0xB1 & 0xB0)  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
MsgVal16-9  
MsgVal32-25  
r
MsgVal8-1  
Message Valid 2 Register  
(addresses 0xB3 & 0xB2)  
MsgVal24-17  
r
MsgVal32-1Message Valid Bits (of all Message Objects)  
one  
This Message Object is configured and should be considered by the Mes-  
sage Handler.  
zero  
This Message Object is ignored by the Message Handler.  
These registers hold the MsgVal bits of the 32 Message Objects. By reading out the MsgVal  
bits, the CPU can check which Message Object is valid. The MsgVal bit of a specific Message  
Object can be set/reset by the CPU via the IFx Message Interface Registers.  
3.5 Registers for Time Triggered Communication  
3.5.1 Trigger Memory Access Register (addresses 0x0F & 0x0E)  
15  
Rd/Wr  
rw  
14  
res  
r
13  
res  
r
12  
res  
r
11  
res  
r
10  
res  
r
9
res  
r
8
res  
r
7
res  
r
6
res  
r
5
res  
r
4
3
2
1
0
Trigger Number  
rw  
Rd/Wr  
Read / Write  
one  
Write to selected Trigger.  
zero  
Read from selected Trigger.  
Trigger Number  
0x00-0x1F  
The trigger is selected for data transfer between Trigger Memory  
and IF1 Message Data B1 and B2 Registers.  
Note : The CPU may access the Trigger Memory only during Configuration Mode. During active mode,  
the write to the Trigger Memory Access register is locked. The Trigger Memory access is  
started by a write to the low byte of the Trigger Memory Access register.  
3.5.2 IF1 Data B1 and B2 Registers for Trigger Memory Access  
The trigger data of the TTCAN system matrix is stored in the Trigger Memory. The Trigger  
Memory is accessed via the IF1 Data B1 and B2 Registers. The data transfer is controlled by  
the Trigger Memory Access Register. The bits of IF1 Data B1 and B2 Registers correspond  
with the bits of a Trigger Memory word according to the following table :  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
IF1 Message Data B1  
IF1 Message Data B2  
Type Message Number  
res  
Cycle_Code  
Time_Mark  
rw  
rw  
Note : Accesses to the Trigger Memory are controlled by the Trigger Memory Access Register, which  
selects a word of the Trigger Memory and specifies the direction of the data transfer.  
On each transfer, 32 bits are loaded either from the IF1 Data B1 and B2 Registers to the  
selected Trigger Memory word or vice versa.  
BOSCH  
- 29/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
In the Trigger Memory, the Triggers must be sorted according to their Time_Marks. There may  
not be two Triggers that are active at the same Cycle Time and Cycle_Count. For details see  
Type  
Trigger Type  
0
1
2
3
4
5
6
7
Tx_Ref_Trigger  
valid when not in Gap  
valid when in Gap  
Start a transmission  
Start a Merged Arbitrating Window  
valid when not in Gap  
valid when in Gap  
Tx_Ref_Trigger_Gap  
Tx_Trigger_Single  
Tx_Trigger_Merged  
Watch_Trigger  
Watch_Trigger_Gap  
Rx_Trigger  
Check for reception  
illegal type, causes config-error  
EndOfList  
Message Number  
0x00  
0x01-0x1F  
Trigger is valid for Message 32  
Trigger is valid for Message 1 to Message 31  
Cycle_Code Cycle_Count for which the Trigger is valid  
0b000000x valid for all Cycles  
0b000001c valid every second Cycle  
0b00001cc valid every fourth Cycle  
0b0001ccc valid every eighth Cycle  
0b001cccc valid every sixteenth Cycle  
at (Cycle_Count mod 2) = c  
at (Cycle_Count mod 4) = cc  
at (Cycle_Count mod 8) = ccc  
at (Cycle_Count mod 16) = cccc  
0b01ccccc valid every thirty-second Cycle at (Cycle_Count mod 32) = ccccc  
0b1cccccc valid every sixty-fourth Cycle at (Cycle_Count mod 64) = cccccc  
Time_Mark  
0x0000-0xFFFF Cycle Time for which the trigger becomes active.  
Note : The Message Number must be “1” for Type Tx_Ref_Trigger and Tx_Ref_Trigger_Gap. The  
Message Number is not regarded for Type Watch_Trigger, Watch_Trigger_Gap, and EndOf-  
List. The Time_Mark is not regarded for Trigger Type EndOfList. The Cycle_Count is only  
regarded for Type Rx_Trigger, Tx_Trigger_Single, and Tx_Trigger_Merged.  
3.5.3 TT Operation Mode Register (addresses 0x29 & 0x28)  
15  
res  
r
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
Init_Ref_Offset  
TM  
rw  
MPR2-0  
rw  
L2 EECS  
TTMode  
rw  
rw  
rw  
rw  
Init_Ref_Offset Initial Reference Trigger Offset  
0x00-0x7F  
positive offset (Initial offset may not be negative).  
TM  
Time Master  
one  
The node is a (potential) Time Master.  
The node will never be a Time Master.  
zero  
MPr2-0  
L2  
Time Master Priority (last three bits of Reference Message’s identifier)  
0x0-0x7  
The priority of this node (0 is highest priority).  
Level 2  
one  
zero  
The node operates in TTCAN Level 2.  
The node operates in TTCAN Level 1.  
BOSCH  
- 30/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
EECS  
Enable External Clock Synchronisation  
one  
TUR Configuration (NumCfg only) may be updated during  
TTCAN operation.  
zero  
TUR Configuration may not be updated.  
TTMode TTCAN Operation Mode  
0x0  
0x1  
0x2  
0x3  
TTMode_0 Event driven CAN Communication (default mode).  
TTMode_1 Configuration Mode.  
TTMode_2 Strictly Time Triggered Operation.  
TTMode_3 Event Synchronised Time Triggered Operation.  
Note : The CPU may write to the TT Operation Mode register only during initialisation (Init and CCE  
are set). Configuration Mode enables the write access to the other TTCAN configuration regis-  
ters. The whole CAN module remains in initialisation mode while TTMode is TTMode_1, “Con-  
figuration Mode”, even if Init is reset.  
The following registers require TTMode_1 “Configuration Mode” to be writable :  
Name  
Reset Value  
Function  
Trigger Memory Access  
TT Operation Mode15-2  
TT Matrix Limits1  
0x0000  
0x0000  
0x0000  
0x0000  
0x0001  
0x0000  
0x1000  
0x0000  
Defines communication schedule  
Time mastership, clock control  
Number of transmissions  
Length of cycle components  
Watchdog service interval  
Length of NTU  
TT Matrix Limits2  
TT Application Watchdog  
TUR-NumeratorCfg  
TUR-DenominatorCfg  
Clock Control15-8  
Length of NTU  
Clock calibration, stopwatch, TMI  
3.5.4 TT Matrix Limits1 Register (addresses 0x2B & 0x2A)  
15  
14  
res  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
ETT  
rw  
r
ETT  
Expected Tx_Trigger  
0x000-0xfFF Expected number of Tx_Triggers in one matrix cycle.  
3.5.5 TT Matrix Limits2 Register (addresses 0x2D & 0x2C)  
15  
14  
13  
12  
11  
10  
TEW  
rw  
9
8
7
6
5
4
3
2
1
0
RDLC  
rw  
res  
CCM  
r
rw  
RDLC  
TEW  
Reference Message Data Length Code  
0x0  
0x1-0xF  
invalid value.  
DLC of Reference Message to transmit when Time Master.  
Tx_Enable Window  
0x0-0xF Length of Tx_Enable Window.  
BOSCH  
- 31/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
CCM  
Cycle_Count_Max (Number of last Basic Cycle in the Matrix Cycle)  
0x00  
0x01  
0x03  
0x07  
0x0F  
0x1F  
0x3F  
other values  
1 Basic Cycle in the Matrix Cycle.  
2 Basic Cycles in the Matrix Cycle.  
4 Basic Cycles in the Matrix Cycle.  
8 Basic Cycles in the Matrix Cycle.  
16 Basic Cycles in the Matrix Cycle.  
32 Basic Cycles in the Matrix Cycle.  
64 Basic Cycles in the Matrix Cycle.  
reserved.  
3.5.6 TT Application Watchdog Limit Register (addresses 0x2F & 0x2E)  
15  
Bark  
rw  
14  
13  
12  
11  
res  
r
10  
9
8
7
6
5
4
3
2
1
0
AppWdL  
rw  
Bark  
The state of the Application_Watchdog  
one  
zero  
The application has failed to serve the watchdog on time.  
The application did serve the watchdog on time.  
AppWdL Application_Watchdog_Limit  
0x00-0xFF  
The maximum time (unit is 256•NTU) after which the application  
has to serve the watchdog again since last time it has served it.  
The application watchdog is served by reading the high byte of the register. When the  
watchdog is not served in time, the bit Bark is set, all TTCAN communication is stopped, and  
the TTCAN module is set into silent mode. The TTCAN module is restarted by writing Bark to  
‘0’ in configuration mode.  
The application watchdog can be disabled by programming the Test Register bit WdOff to ‘1’  
3.5.7 TT Interrupt Enable Register (addresses 0x31 & 0x30)  
15  
CfE  
rw  
14  
ApW WTr IWT CEL TxO TxU GTE Dis GTW SWE TMI SoG CSM SSM SBC  
rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
There is for each bit in the TT Interrupt Vector register one corresponding enable bit in the TT  
Interrupt Enable register, ‘1’ meaning enabled and ‘0’ meaning disabled. The TT Interrupt  
Vector register bits will be updated regardless of the TT Interrupt Enable register bits, the  
enable bits control whether an interrupt will be generated when the matching bit in the TT  
Interrupt Vector register is set to ‘1’ (and when the module interrupt is enabled by IE = ‘1’ in the  
CAN Control register).  
3.5.8 TT Interrupt Vector Register (addresses 0x33 & 0x32)  
The individual TT Interrupt Vector register bits are set to ‘1’ when their specific interrupt  
condition is met, an interrupt will be generated as long as both an Interrupt Vector bit and the  
corresponding Interrupt Enable bits are set. The Interrupt Vector register bits will not be  
cleared automatically; with the exception of hardware reset, they can only be cleared by the  
CPU. The CPU cannot write the Interrupt Vector register bits to ‘1’, but it can write them to ‘0’.  
BOSCH  
- 32/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
Any number of bits may be written to ‘0’ (cleared) at the same time. Bits that are written to ‘1’  
remain unchanged.  
15  
CfE  
rw  
14  
ApW WTr IWT CEL TxO TxU GTE Dis GTW SWE TMI SoG CSM SSM SBC  
rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
CfE  
Config Error  
Set when an error is found in the Trigger List.  
ApW  
WTr  
IWT  
Application Watchdog  
Set when the application watchdog was not served in time.  
Watch Trigger  
Set when a Watch Trigger became active (missing Reference Message).  
Initialisation Watch Trigger  
Set when an Initialisation Watch Trigger became active (no system start-up).  
Note : The initialisation is restarted by resetting IWT.  
CEL  
TxO  
TxU  
GTE  
Dis  
Change of Error Level  
Set when the Error Level changed.  
Tx_Count Overflow  
Set when the FSE sees more than Expected_Tx_Trigger in one Matrix Cycle.  
Tx_Count Underflow  
Set when the FSE sees less than Expected_Tx_Trigger in one Matrix Cycle.  
Global Time Error  
Set when Synchronisation Deviation SD exceeds specified limit SDL (level2 only).  
Global Time Discontinuity  
Set on discontinuity of the Global Time (Disc_Bit in the Reference Message).  
GTW  
SWE  
TMI  
Global Time Wrap  
Set when a Global Time wrap occurred (from 0xFFFF to 0x0000).  
Stop Watch Event  
Set when a rising edge is detected at the STOP_WATCH_TRIGGER pin.  
Time Mark Interrupt  
Set when the selected time equals value in Time Mark register.  
SoG  
CSM  
SSM  
SBC  
Start of Gap  
Set when a Gap is detected (Next_is_Gap bit in the Reference Message).  
Change of Synchronisation Mode  
Set when the master to slave relation or the schedule synchronisation changed.  
Start of System Matrix Cycle  
Set when a new System Matrix Cycle has started.  
Start of Basic Cycle  
Set when a new Basic Cycle has started.  
BOSCH  
- 33/77 -  
11.11.02  
 
User’s Manual  
3.5.9 TT Global Time Register (addresses 0x35 & 0x34)  
TTCAN  
Revision 1.6  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
Global_Time  
r
r
Global_Time Global Time of the TTCAN network  
0x0000-0xFFFF Actual Global Time value.  
3.5.10 TT Cycle Time Register (addresses 0x37 & 0x36)  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
4
4
3
3
3
2
2
2
1
1
1
0
0
0
Cycle_Time  
r
r
Cycle_Time Cycle Time of the TTCAN basic cycle  
0x0000-0xFFFF Actual Cycle Time value.  
3.5.11 TT Local Time Register (addresses 0x39 & 0x38)  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
Local_Time  
r
r
Local_Time Local Time of the TTCAN node  
0x0000-0xFFFF Actual Local Time value.  
3.5.12 TT Master State Register (addresses 0x3B & 0x3A)  
15  
14  
13  
12  
11  
10  
9
8
7
WfE  
r
6
5
RTO  
r
TMP2-0  
SyncSt  
MState  
r
r
r
RTO  
Ref_Trigger_Offset  
0x00-0xFF  
The actual value of the Ref_Trigger_Offset.  
WfE  
Wait for Event  
one  
The node waits for event triggered Reference Message.  
The node does not wait for event triggered Reference Message.  
zero  
TMP2-0  
SyncSt  
Time Master Priority  
0x0-0x7  
The priority of the actual Time Master.  
TTCAN Synchronisation State  
0x0  
0x1  
0x2  
0x3  
Out of Synchronisation  
Synchronising to TTCAN communication  
In_Gap, Schedule suspended by Gap  
In_Schedule, Synchronised to Schedule  
MState  
TTCAN Master State and Operating Mode  
0x0  
0x1  
0x2  
0x3  
Node does not take part in TTCAN communication  
Node is operating as Time Slave  
Node is operating as Backup Time Master  
Node is operating as Current Time Master  
BOSCH  
- 34/77 -  
11.11.02  
 
       
User’s Manual  
3.5.13 TT Cycle Count Register (addresses 0x3D & 0x3C)  
TTCAN  
Revision 1.6  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
reserved  
res  
C_Cnt5-0  
r
r
r
C_Cnt5-0 Cycle_Count  
0x00-0x3F The number of the actual Basic Cycle in the System Matrix.  
3.5.14 TT Error Level Register (addresses 0x3F & 0x3E)  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
reserved  
MSCmax  
MSCmin  
TTEL  
r
r
r
r
MSCmax Maximum Message Status Count  
0x0-0x7 The highest Message Status Count of all periodic Message Objects.  
MSCmin Minimum Message Status Count  
0x0-0x7 The lowest Message Status Count of all periodic Message Objects.  
TTEL  
TT Error Level  
0x0  
0x1  
0x2  
0x3  
severity 0 : No Error  
severity 1 : Warning  
severity 2 : Error  
severity 3 : Fatal Error  
3.5.15 TUR Numerator Configuration Low Register (addresses 0x57 & 0x56)  
15  
14  
13  
12  
rw  
11  
10  
9
8
7
6
5
4
3
2
1
0
NumCfgL  
rw  
NumCfgL TUR Numerator Configuration (low part)  
0x0000-0xFFFF NumCfg[150]  
NumCfg is an 18-bit value. Its high part, NumCfg[1716] is hard wired to 0b01. The range of  
NumCfg is [0x100000x1FFFF]. The value configured in NumCfg is the initial value for  
NumAct, so when the number 0xnnnn is written to NumCfg[150], NumAct starts with the  
value 0x1nnnn. NumCfgL may be written during Configuration Mode or if EESC (Enable  
External Clock Synchronisation) is set. When a new value for NumCfgL is written after  
Configuration Mode, the new value takes effect when the ECS bit of the TT Clock Control  
register is written to ‘1’.  
Note : The actual value of TUR may be changed by the clock drift compensation function of TTCAN  
Level 2 in order to adjust the node’s local view of the NTU to the time master view of the NTU.  
DenomCfg will not be changed by the automatic drift compensation, NumAct may be adjusted  
in the range of the Synchronisation Deviation Limit around NumCfg. NumCfg and DenomCfg  
should be programmed to the largest suitable values in order to allow the best computational  
accuracy for the drift compensation process.  
BOSCH  
- 35/77 -  
11.11.02  
 
     
User’s Manual  
3.5.16 TUR Denominator Configuration Register (addresses 0x59 & 0x58)  
TTCAN  
Revision 1.6  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
res  
DenomCfg[130]  
r
rw  
DenomCfg[130] TUR Denominator Configuration  
0x0000 Illegal value.  
0x0001-0x3FFF DenomCfg[130].  
The length of the NTU is given by (NumCfg • System Clock Period) = (DenomCfg NTU), or  
NTU = System Clock Period • NumCfg/DenomCfg.  
DenomCfg is set to 0x1000 by hardware reset and it may not be written to 0x0000. For  
TTCAN Level 2 it is required that NumCfg8•DenomCfg. For TTCAN Level 1 it is required  
that NumCfg4•DenomCfg and NTU=CAN bit time. Write access to the TUR Denominator  
Configuration Register is only possible during Configuration Mode and additionally requires  
that ELT = ’0’.  
Note : If NumCfg<7•DenomCfg in TTCAN Level 1, then it is required that subsequent Time_Marks in  
the Trigger Memory must differ by at least 2 NTU.  
3.5.17 TUR Numerator Actual Registers (addresses 0x5B & 0x5A)  
TUR Numerator ActualL Register 15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
(addresses 0x5B & 0x5A)  
NumAct[158]  
NumAct[70]  
res NumAct[17,16]  
TUR Numerator ActualH Register  
(addresses 0x5D & 0x5C)  
res  
r
r
NumAct TUR Numerator Actual Value  
0x0EFFF  
0x0F000-0x20FFF NumAct[170].  
0x21000 invalid value.  
invalid value.  
There is no drift compensation in TTCAN Level 1, NumAct = NumCfg. In TTCAN Level 2, the  
drift between local clock and the time master’s local clock is calculated. The drift is  
compensated when the Synchronisation Deviation (difference between NumCfg and the  
(ldSDL+5)  
calculated new NumAct) is not more than 2  
. With ldSDL7, this results in a  
maximum range for NumAct of (NumCfg - 0x1000) NumAct (NumCfg + 0x1000)  
3.5.18 TT Stop_Watch Register (addresses 0x61 & 0x60)  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
Stop_Watch  
r
r
Stop_Watch Stop Watch Register  
0x0000-0xFFFF Stop_Watch[150]  
On a rising edge of the STOP_WATCH_TRIGGER pin, when SWS in the TT Clock Control  
Register is > 0 and SWE in the TT Interrupt Vector register is ‘0’, the actual value of the time  
selected by SWS will be copied into the Stop_Watch register and SWE will be set to ‘1’.  
Note : The next Stop_Watch timing will be enabled by resetting SWE to ‘0’.  
BOSCH  
- 36/77 -  
11.11.02  
 
       
User’s Manual  
3.5.19 TT Global Time Preset Register (addresses 0x65 & 0x64)  
TTCAN  
Revision 1.6  
15  
14  
13  
12  
rw  
11  
10  
9
8
7
6
5
4
3
2
1
0
GTDiff  
rw  
GTDiff  
Global Time Preset  
0x0000-0x7FFF Master_Ref_Mark = Master_Ref_Mark + GTDiff.  
0x8000 reserved.  
0x8001-0xFFFF Master_Ref_Mark = Master_Ref_Mark - (0x10000-GTDiff).  
The Global Time Preset takes effect when the node is the current Time Master and when ‘1’ is  
written to SGT in the TT Clock Control register. The next Reference Message will be  
transmitted with the modified Master_Ref_Mark and with Disc_Bit = ‘1’, presetting the Global  
Time in all nodes simultaneously.  
GTDiff is reset to 0x0000 each time a Reference Message with Disc_Bit = ‘1’ becomes valid  
or if the node is not the current time master.  
GTDiff is locked (and WGTD is ‘1’) after setting SGT until the Reference Message with  
Disc_Bit = ‘1’ becomes valid or until the node is no longer the current time master.  
3.5.20 TT Clock Control Register (addresses 0x67 & 0x66)  
15  
14  
ldSDL  
rw  
13  
12  
QCS QGTP ECAL EGTF ELT  
rw rw rw  
11  
10  
9
8
7
6
5
4
3
2
1
0
TMC  
rw  
DET ECS  
rw rw  
SWS  
WGTD SGT  
rw  
r
r
rw  
r
ldSDL  
QCS  
ld(Synchronisation Deviation Limit)  
0x0-0x7 Synchronisation Deviation 2  
Quality of Clock Speed  
(ldSDL + 5)  
.
one  
zero  
SD SDL (always true in TTCAN Level 1).  
Local clock speed not synchronised to Time Master clock speed.  
QGTP  
ECAL  
EGTF  
ELT  
Quality of Global Time Phase  
one  
zero  
Global Time in phase with Time Master.  
Global Time not valid (always true in TTCAN Level 1).  
Enable Clock Calibration  
one  
zero  
The automatic clock calibration in TTCAN Level2 is enabled.  
The automatic clock calibration in TTCAN Level2 is disabled.  
Enable Global Time Filtering  
one  
zero  
The Global Time filtering in TTCAN Level2 is enabled.  
The Global Time filtering in TTCAN Level2 is disabled.  
Enable Local Time  
one  
zero  
The Local Time is enabled.  
The Local Time is stopped (default after hardware reset).  
Note : ELT can only be written during Configuration Mode. It may not be set before the TUR configura-  
tion registers are programmed. Once the Local Time is started, is remains active until the CPU  
writes ELT to ‘0’ or until the next hardware reset. Local Time is also started by resetting Init in  
the CAN Control register.  
BOSCH  
- 37/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
TMC  
Time Mark Compare  
0x0  
0x1  
0x2  
0x3  
No Time Mark interrupt is generated.  
Time Mark interrupt if (Time Mark = Cycle Time).  
Time Mark interrupt if (Time Mark = Local Time).  
Time Mark interrupt if (Time Mark = Global Time).  
DET  
ECS  
SWS  
Disable External Time Mark Port  
one  
zero  
The Time Mark port is disabled.  
The Time Mark port is enabled.  
External Clock Synchronisation  
The External Clock Synchronisation takes effect when ‘1’ is written to ECS.  
ECS will always be read as ‘0’  
Stop Watch Source (when edge is detected at the STOP_WATCH_TRIGGER pin)  
0x0  
0x1  
0x2  
0x3  
Stop Watch is disabled.  
Actual value of Cycle Time is copied to Stop_Watch.  
Actual value of Local Time is copied to Stop_Watch.  
Actual value of Global Time is copied to Stop_Watch.  
WGTD  
SGT  
Wait for Global Time Discontinuity  
one  
The node waits for the completion of a Reference Message with  
Disc_Bit = ‘1’ after SGT has been set by the CPU. GTDiff is  
locked while WGTD is set.  
zero  
No Global Time Preset is pending.  
Set Global Time  
The Global Time Preset takes effect when ‘1’ is written to SGT.  
SGT will always be read as ‘0’.  
The Synchronisation Deviation SD is the difference between NumCfg and NumAct. When the  
(ldSDL + 5)  
calculated NumAct deviates by more than 2  
from NumCfg, the drift compensation is  
suspended and the GTE interrupt is activated. There is no drift compensation in Level 1.  
ECS schedules the updated NumCfg value for activation by the next Reference Message.  
SGT schedules the GTDiff value for activation by the next Reference Message.  
Setting of ECS and SGT requires EECS to be set and the node to be the actual Time Master.  
3.5.21 TT Sync_Mark Register (addresses 0x69 & 0x68)  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
Sync_Mark  
r
r
Sync_MarkSynchronisation Mark  
0x0000-0xFFFF Cycle Time.  
The TT Sync_Mark register shows the Sync_Mark captured at the Start of Frame of each  
message, measured in Cycle Time. The register is updated when the message becomes valid  
and retains its value until the next message becomes valid.  
BOSCH  
- 38/77 -  
11.11.02  
 
 
User’s Manual  
3.5.22 TT Time Mark Register (addresses 0x6D & 0x6C)  
TTCAN  
Revision 1.6  
15  
14  
13  
12  
rw  
11  
10  
9
8
7
6
5
4
3
2
1
0
TMark  
rw  
TMark  
Time Mark  
0x0000-0xFFFF An interrupt is generated when the time base indicated by TMC  
(Cycle Time, Local Time, or Global Time) has the same value as  
Time Mark.  
Note : The Time Mark register can only be written while the time mark interrupt is disabled by TMC= 0.  
3.5.23 TT Gap Control Register (addresses 0x6F & 0x6E)  
15  
14  
13  
12  
res  
11  
10  
9
8
7
6
5
4
3
res  
r
2
1
0
EPE res TMG FGp  
rw rw rw  
Gap GpH NiG  
r
r
r
r
rw  
EPE  
Event Pin Enable  
one  
The EVENT_TRIGGER pin controls the Gaps.  
zero  
The application program controls the Gaps.  
TMG  
FGp  
Time Mark Gap  
one  
The next Reference Message is started when the Time Mark  
Interrupt TMI becomes active.  
The bit is reset automatically at each Reference Message.  
zero  
Finish Gap  
one  
The next Reference Message is started immediately when  
Gap = ‘1’ or else at the next Tx_Ref_Trigger. This bit is set in  
TTMODE_3 by the CPU, by a Time Mark Interrupt if TMG = ‘1’,  
or by EVENT_TRIGGER pin = ‘0’ if EPE = ‘1’.  
zero  
The bit is reset automatically at each Reference Message.  
Gap  
GpH  
NiG  
Now is Gap  
one  
zero  
The Gap time after the Basic Cycle has started and TTMODE_3.  
No Gap in Schedule, this bit is reset automatically at each Refer-  
ence Message and in nodes that are time slaves.  
Gap Herald  
one  
zero  
Next_is_Gap = ‘1’ in Reference Message and TTMODE_3.  
No Gap announced, this bit is reset automatically at each Refer-  
ence Message with Next_is_Gap = ‘0’.  
Next is Gap  
one  
Next_is_Gap = ‘1’ will be transmitted in next Reference Mes-  
sage(s). This bit can only be set by the CPU in a node that is the  
actual time master operating in TTMODE_3.  
zero  
No action. The bit is reset automatically when any Reference  
Message transmitted by another node is received.  
The time master writes NiG to ‘1’ to initiate a Gap. The Next_is_Gap bit will be transmitted as  
‘1’ in the next Reference Message. As soon as that Reference Message is completed, the  
GpH bit will announce the Gap to the time master as well as to the time slaves. The current  
BOSCH  
- 39/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
basic cycle will continue until its last time window. The time after the last time window is the  
Gap time.  
In nodes that are time slaves, the Gap bit will remain at ‘0’. In the actual time master and in  
potential time masters, the Gap bit will be set when the last basic cycle has finished and the  
Gap time starts.  
The Gap is finished by setting FGp to ‘1’. There are three ways to set FGp. FGp can be set by  
the CPU directely. Another method to set FGp is using the TMI interrupt: When TMG is set to  
‘1’, the next TMI will set FGp. The third way to set FGp is using the EVENT_TRIGGER input  
pin: When EPE is set to ‘1’, an edge from high to low at the EVENT_TRIGGER will set FGp.  
When FGp is set after the Gap time has started, that event will start the transmission of a  
Reference Message immediately and will thereby synchronise the message schedule.  
When FGp is set before the Gap time has started (when the Basic Cycle is still in progress),  
the next Reference Message will be started at the end of the Basic Cycle, at the  
Tx_Ref_Trigger – there will be no Gap time in the message schedule.  
BOSCH  
- 40/77 -  
11.11.02  
 
User’s Manual  
TTCAN  
Revision 1.6  
4. CAN Application  
The TTCAN module can emulate a C_CAN module in ordinary event driven ISO 11898-1 CAN  
communication. C_CAN software can also be used for the TTCAN, provided that the TTCAN’s  
application watchdog is disabled in the configuration phase, as described in chapter 2.3.4.2.  
The registers of the TTCAN module are subdivided into three classes: configuration registers,  
status registers, and application registers. The configuration registers are used only in the  
initialisation of the module. The application and status registers provide access to the CAN  
messages and give information on the CAN communication, interfacing between the internal  
message handling and the application program.  
4.1 Internal CAN Message Handling  
The Message Handler FSM controls the data transfer between the Rx/Tx Shift Register of the  
CAN Core, the Message RAM and the IFx Registers, performing the following tasks:  
Data Transfer from IFx Registers to the Message RAM.  
Data Transfer from Message RAM to the IFx Registers.  
Data Transfer from Message RAM to CAN_Core (messages to be transmitted).  
Data Transfer from CAN_Core to the Acceptance Filtering unit.  
Scanning of Message RAM for a matching Message Object (acceptance filtering).  
Data Transfer from CAN_Core to the Message RAM (received messages).  
Handling of TxRqst flags.  
Handling of interrupts.  
4.1.1 Data Transfer Between IFx Registers and Message RAM  
There are two sets of IFx Registers. Each set of IFx Registers consists of Command  
Registers, controlling the data transfer, and Message Buffer Registers, containing the  
Message Object.  
The Command Request Register addresses the desired Message Object in the Message  
RAM, the respective Command Mask Register specifies whether a complete Message Object  
or only parts of it will be transferred. The data transfer is initiated by writing to the Command  
Request Register.  
Due to the structure of the Message RAM, it is not possible to change single bits/bytes of one  
Message Object, it is always necessary to access a complete Message Object in the Message  
RAM. Therefore the data transfer from the IFx Registers to the Message RAM requires the  
Message Handler FSM to perform a read-modify-write cycle. First those parts of the Message  
Object that are not to be changed are read from the Message RAM into the Message Buffer  
Registers, and then the complete contents of the Message Buffer Registers are written into  
the Message Object.  
After the partial write of a Message Object, that Message Buffer Registers that are not  
selected in the Command Mask Register will be set to the actual contents of the selected  
Message Object.  
After the partial read of a Message Object, that Message Buffer Registers that are not  
selected in the Command Mask Register will be left unchanged.  
manual_can_application.fm  
BOSCH  
- 41/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
When the CPU initiates a data transfer between the IFx Registers and Message RAM, the  
Message Handler sets the Busy bit in the respective Command Request Register to ‘1’. After  
the transfer has completed, the Busy bit is set back to ‘0’ (see figure 8). If the optional wait-  
function is implemented in the module’s CPU interface, the CPU is halted while the Busy bit is  
START  
No  
Write Command Request Register  
Yes  
Busy = 1  
No  
Yes  
WR/RD = 1  
Read Message Object to IFx  
Write IFx to Message RAM  
Read Message Object to IFx  
Busy = 0  
Figure 8: Data Transfer between IFx Registers and Message RAM  
4.1.2 Transmission of Messages in Event Driven CAN Communication  
If the shift register of the CAN_Core cell is ready for loading and if there is no data transfer  
between the IFx Registers and Message RAM, the MsgVal bits in the Message Valid Register  
TxRqst bits in the Transmission Request Register are evaluated. The valid Message Object  
with the highest priority pending transmission request is loaded into the shift register by the  
Message Handler and the transmission is started. The Message Object’s NewDat bit is reset.  
After a successful transmission and if no new data was written to the Message Object  
(NewDat = ‘0’) since the start of the transmission, the TxRqst bit will be reset. If TxIE is set,  
IntPnd will be set after a successful transmission. If the TTCAN has lost the arbitration or if an  
error occurred during the transmission, the message will be retransmitted as soon as the CAN  
bus is free again. If meanwhile the transmission of a message with higher priority has been  
requested, the messages will be transmitted in the order of their priority.  
If DAR is set (Disable Automatic Retransmission), TxRqst will be reset when the message is  
loaded into the CAN_Core, NewDat will be reset after the successful transmission.  
BOSCH  
- 42/77 -  
11.11.02  
 
     
User’s Manual  
4.1.3 Acceptance Filtering of Received Messages  
TTCAN  
Revision 1.6  
When the arbitration and control field (Identifier + IDE + RTR + DLC) of an incoming message  
is completely shifted into the shift register of the CAN_Core, the Message Handler FSM starts  
the scanning of the Message RAM for a matching valid Message Object.  
To scan the Message RAM for a matching Message Object, the Acceptance Filtering unit is  
loaded with the arbitration bits from the CAN_Core shift register. Then the arbitration and  
mask fields (including MsgVal, UMask, NewDat, and EoB) of Message Object 1 are loaded  
into the Acceptance Filtering unit and compared with the arbitration field from the shift register.  
This is repeated with each following Message Object until a matching Message Object is  
found or until the end of the Message RAM is reached.  
If a match occurs, the scanning is stopped and the Message Handler FSM proceeds  
depending on the type of frame (Data Frame or Remote Frame) received.  
4.1.3.1 Reception of Data Frame  
The Message Handler FSM stores the message from the CAN_Core shift register into the  
respective Message Object in the Message RAM. Not only the data bytes, but all arbitration  
bits and the Data Length Code are stored into the corresponding Message Object. This is  
implemented to keep the data bytes connected with the identifier even if arbitration mask  
registers are used.  
The NewDat bit is set to indicate that new data (not yet seen by the CPU) has been received.  
The CPU should reset NewDat when it reads the Message Object. If at the time of the  
reception the NewDat bit was already set, MsgLst is set to indicate that the previous data  
(supposedly not seen by the CPU) is lost. If the RxIE bit is set, the IntPnd bit is set, causing  
the Interrupt Register to point to this Message Object.  
The TxRqst bit of this Message Object is reset to prevent the transmission of a Remote  
Frame, while the requested Data Frame has just been received.  
4.1.3.2 Reception of Remote Frame  
When a Remote Frame is received, three different configurations of the matching Message  
Object have to be considered:  
1) Dir = ‘1’ (direction = transmit), RmtEn = ‘1’, UMask = ‘1’ or ‘0’  
The TxRqst bit of this Message Object is set at the reception of a matching Remote Frame.  
The rest of the Message Object remains unchanged.  
2) Dir = ‘1’ (direction = transmit), RmtEn = ‘0’, UMask = ‘0’  
The Remote Frame is ignored, this Message Object remains unchanged.  
3) Dir = ‘1’ (direction = transmit), RmtEn = ‘0’, UMask = ‘1’  
The Remote Frame is treated similar to a received Data Frame. At the reception of a matching  
Remote Frame, the TxRqst bit of this Message Object is reset. The arbitration and control  
field (Identifier + IDE + RTR + DLC) from the shift register is stored into the Message Object in  
the Message RAM and the NewDat bit of this Message Object is set. The data field of the  
Message Object remains unchanged.  
4.1.4 Storing Received Messages in FIFO Buffers  
Several Message Objects may be grouped to form one or more FIFO Buffers, each FIFO  
Buffer configured to store received messages with a particular (group of) Identifier(s).  
Arbitration and Mask Registers of the FIFO Buffer’s Message Objects are identical. The EoB  
(End of Buffer) bits of all but the last of the FIFO Buffer’s Message Objects are ‘0’, in the last  
one the EoB bit is ‘1’.  
BOSCH  
- 43/77 -  
11.11.02  
 
           
User’s Manual  
TTCAN  
Revision 1.6  
Received messages with identifiers matching to a FIFO Buffer are stored into a Message  
Object of this FIFO Buffer, starting with the Message Object with the lowest message number.  
When a message is stored into a Message Object of a FIFO Buffer the NewDat bit of this  
Message Object is set. By setting NewDat while EoB is ‘0’ the Message Object is locked for  
further write accesses by the Message Handler until the CPU has cleared the NewDat bit.  
Messages are stored into a FIFO Buffer until the last Message Object of this FIFO Buffer is  
reached. If none of the preceding Message Objects is released by writing NewDat to ‘0’, all  
further messages for this FIFO Buffer will be written into the last Message Object of the FIFO  
Buffer (EoB = ‘1’) and therefore overwrite previous messages.  
4.1.5 Receive / Transmit Priority  
The receive/transmit priority for the Message Objects is attached to the message number, not  
to the CAN identifier. Message Object 1 has the highest priority, while Message Object 32 has  
the lowest priority. If more than one transmission request is pending, they are serviced due to  
the priority of the corresponding Message Object, so the messages with the highest priority  
should be placed in the Message Objects with the lowest numbers.  
4.2 Configuration of the Module  
After the hardware reset, the Init bit in the CAN Control Register is set and all CAN protocol  
functions are disabled. The configuration of the module (bit timing and Message Objects) has  
to be completed before the CAN protocol functions are enabled.  
The configuration of the bit timing requires that the CCE bit in the CAN Control Register is set  
additionally to Init. This is not required for the configuration of the Message Objects.  
The configuration of the TTCAN functions (see chapter 5) requires that TTMode is set to  
“Configuration Mode”.  
The bits MsgVal, NewDat, IntPnd, and TxRqst of the Message Objects are reset to ‘0’ by the  
hardware reset, the other contents of the Message RAM are not affected by a hardware reset.  
The configuration of a Message Object is done by programming Mask, Arbitration, Control and  
Data field of one of the two interface register sets to the desired values. By writing to the  
corresponding IFx Command Request Register, the IFx Message Buffer Registers are loaded  
into the addressed Message Object in the Message RAM.  
All the Message Objects must be initialized by the CPU or they must be not valid, and the bit  
timing must be configured before the CPU clears the Init bit in the CAN Control Register.  
The CPU may enable the interrupt line (setting IE to ‘1’) at the same time when it clears Init  
and CCE. The status interrupts EIE and SIE may be enabled simultaneously. If EIE is enabled,  
a status interrupt will be generated each time one of the error counters reaches or leaves the  
error warning level of 96 of when the Bus_Off state changes. If SIE is enabled, an interrupt will  
be generated each time when a message transfer is successfully completed or a CAN bus  
error is detected. The Last Error Code LEC in the Status Register allows the interrupt service  
routine to analyse the CAN bus errors.  
When the Init bit in the CAN Control Register is cleared, the CAN Protocol Controller state  
machine of the CAN_Core and the Message Handler State Machine control the TTCAN’s  
internal data flow. Received messages that pass the acceptance filtering are stored into the  
Message RAM, messages with pending transmission request are loaded into the CAN_Core’s  
Shift Register and are transmitted via the CAN bus.  
BOSCH  
- 44/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
4.2.1 Configuration of the Bit Timing  
Even if minor errors in the configuration of the CAN bit timing do not result in immediate  
failure, the performance of a CAN network can be reduced significantly.  
In many cases, the CAN bit synchronisation will amend a faulty configuration of the CAN bit  
timing to such a degree that only occasionally an error frame is generated. In the case of  
arbitration however, when two or more CAN nodes simultaneously try to transmit a frame, a  
misplaced sample point may cause one of the transmitters to become error passive.  
The analysis of such sporadic errors requires a detailed knowledge of the CAN bit  
synchronisation inside a CAN node and of the CAN nodes’ interaction on the CAN bus.  
4.2.1.1 Bit Time and Bit Rate  
CAN supports bit rates in the range of lower than 1 KBit/s up to 1000 kBit/s. Each member of  
the CAN network has its own clock generator, usually a quartz oscillator. The timing parameter  
of the bit time (i.e. the reciprocal of the bit rate) can be configured individually for each CAN  
node, creating a common bit rate even though the CAN nodes’ oscillator periods (f ) may be  
osc  
different.  
The frequencies of these oscillators are not absolutely stable, small variations are caused by  
changes in temperature or voltage and by deteriorating components. As long as the variations  
remain inside a specific oscillator tolerance range (df), the CAN nodes are able to compensate  
for the different bit rates by resynchronising to the bit stream.  
According to the CAN specification, the bit time is divided into four segments (see figure 9).  
The Synchronisation Segment, the Propagation Time Segment, the Phase Buffer Segment 1,  
and the Phase Buffer Segment 2. Each segment consists of a specific, programmable number  
of time quanta (see Table 1). The length of the time quantum (t , which is the basic time unit  
q)  
of the bit time, is defined by the CAN controller’s system clock f  
and the Baud Rate  
sys  
Prescaler (BRP): t = BRP / f . The TTCAN’s system clock f is the frequency of its  
q
sys  
sys  
CAN_CLK input.  
Nominal CAN Bit Time  
Phase_Seg1  
Sync_ Prop_Seg  
Seg  
Phase_Seg2  
1 Time Quantum  
( t )  
Sample Point  
q
Figure 9: Bit Timing  
The Synchronisation Segment Sync_Seg is that part of the bit time where edges of the CAN  
bus level are expected to occur; the distance between an edge that occurs outside of  
Sync_Seg and the Sync_Seg is called the phase error of that edge. The Propagation Time  
Segment Prop_Seg is intended to compensate for the physical delay times within the CAN  
network. The Phase Buffer Segments Phase_Seg1 and Phase_Seg2 surround the Sample  
Point. The (Re-)Synchronisation Jump Width (SJW) defines how far a resynchronisation may  
move the Sample Point inside the limits defined by the Phase Buffer Segments to compensate  
for edge phase errors.  
BOSCH  
- 45/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
A given bit rate may be met by different bit time configurations, but for the proper function of  
the CAN network the physical delay times and the oscillator’s tolerance range have to be  
considered.  
Parameter  
Range  
Remark  
1 32  
defines the length of the time quantum  
BRP  
[
]
t
q
Sync_Seg  
Prop_Seg  
Phase_Seg1  
Phase_Seg2  
SJW  
1
fixed length, synchronisation of bus input to system clock  
compensates for the physical delay times  
t
q
[1 8]  
[1 8]  
[1 8]  
[1 4]  
t
q
q
q
q
may be lengthened temporarily by synchronisation  
may be shortened temporarily by synchronisation  
may not be longer than either Phase Buffer Segment  
t
t
t
This table describes the minimum programmable ranges required by the CAN protocol  
Table 1 : Parameters of the CAN Bit Time  
4.2.1.2 Propagation Time Segment  
This part of the bit time is used to compensate physical delay times within the network. These  
delay times consist of the signal propagation time on the bus and the internal delay time of the  
CAN nodes.  
Any CAN node synchronised to the bit stream on the CAN bus will be out of phase with the  
transmitter of that bit stream, caused by the signal propagation time between the two nodes.  
The CAN protocol’s non-destructive bitwise arbitration and the dominant acknowledge bit  
provided by receivers of CAN messages require that a CAN node transmitting a bit stream  
must also be able to receive dominant bits transmitted by other CAN nodes that are  
synchronised to that bit stream. The example in figure 10 shows the phase shift and  
propagation times between two CAN nodes.  
Sync_Seg  
Prop_Seg  
Phase_Seg1  
Phase_Seg2  
Node B  
Node A  
Delay A_to_B  
Delay B_to_A  
Delay A_to_B >= node output delay(A) + bus line delay(AB) + node input delay(B)  
Prop_Seg  
Prop_Seg  
>= Delay A_to_B + Delay B_to_A  
>= 2 • [max(node output delay+ bus line delay + node input delay)]  
Figure 10: The Propagation Time Segment  
In this example, both nodes A and B are transmitters performing an arbitration for the CAN  
bus. The node A has sent its Start of Frame bit less than one bit time earlier than node B,  
therefore node B has synchronised itself to the received edge from recessive to dominant.  
Since node B has received this edge delay(A_to_B) after it has been transmitted, B’s bit timing  
segments are shifted with regard to A. Node B sends an identifier with higher priority and so it  
will win the arbitration at a specific identifier bit when it transmits a dominant bit while node A  
BOSCH  
- 46/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
transmits a recessive bit. The dominant bit transmitted by node B will arrive at node A after the  
delay(B_to_A).  
Due to oscillator tolerances, the actual position of node A’s Sample Point can be anywhere  
inside the nominal range of node A’s Phase Buffer Segments, so the bit transmitted by node B  
must arrive at node A before the start of Phase_Seg1. This condition defines the length of  
Prop_Seg.  
If the edge from recessive to dominant transmitted by node B would arrive at node A after the  
start of Phase_Seg1, it could happen that node A samples a recessive bit instead of a  
dominant bit, resulting in a bit error and the destruction of the current frame by an error flag.  
The error occurs only when two nodes arbitrate for the CAN bus that have oscillators of  
opposite ends of the tolerance range and that are separated by a long bus line; this is an  
example of a minor error in the bit timing configuration (Prop_Seg to short) that causes  
sporadic bus errors.  
Some CAN implementations provide an optional 3 Sample Mode The TTCAN does not. In this  
mode, the CAN bus input signal passes a digital low-pass filter, using three samples and a  
majority logic to determine the valid bit value. This results in an additional input delay of 1 t ,  
q
requiring a longer Prop_Seg.  
4.2.1.3 Phase Buffer Segments and Synchronisation  
The Phase Buffer Segments (Phase_Seg1 and Phase_Seg2) and the Synchronisation Jump  
Width (SJW) are used to compensate for the oscillator tolerance. The Phase Buffer Segments  
may be lengthened or shortened by synchronisation.  
Synchronisations occur on edges from recessive to dominant, their purpose is to control the  
distance between edges and Sample Points.  
Edges are detected by sampling the actual bus level in each time quantum and comparing it  
with the bus level at the previous Sample Point. A synchronisation may be done only if a  
recessive bit was sampled at the previous Sample Point and if the actual time quantum’s bus  
level is dominant.  
An edge is synchronous if it occurs inside of Sync_Seg, otherwise the distance between edge  
and the end of Sync_Seg is the edge phase error, measured in time quanta. If the edge occurs  
before Sync_Seg, the phase error is negative, else it is positive.  
Two types of synchronisation exist: Hard Synchronisation and Resynchronisation. A Hard  
Synchronisation is done once at the start of a frame; inside a frame only Resynchronisations  
occur.  
Hard Synchronisation  
After a hard synchronisation, the bit time is restarted with the end of Sync_Seg, regardless of  
the edge phase error. Thus hard synchronisation forces the edge which has caused the hard  
synchronisation to lie within the synchronisation segment of the restarted bit time.  
Bit Resynchronisation  
Resynchronisation leads to a shortening or lengthening of the bit time such that the position  
of the sample point is shifted with regard to the edge.  
When the phase error of the edge which causes Resynchronisation is positive, Phase_Seg1  
is lengthened. If the magnitude of the phase error is less than SJW, Phase_Seg1 is length-  
ened by the magnitude of the phase error, else it is lengthened by SJW.  
BOSCH  
- 47/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
When the phase error of the edge which causes Resynchronisation is negative, Phase_Seg2  
is shortened. If the magnitude of the phase error is less than SJW, Phase_Seg2 is shortened  
by the magnitude of the phase error, else it is shortened by SJW.  
When the magnitude of the phase error of the edge is less than or equal to the programmed  
value of SJW, the results of Hard Synchronisation and Resynchronisation are the same. If the  
magnitude of the phase error is larger than SJW, the Resynchronisation cannot compensate  
the phase error completely, an error of (phase error - SJW) remains.  
Only one synchronisation may be done between two Sample Points. The synchronisations  
maintain a minimum distance between edges and Sample Points, giving the bus level time to  
stabilize and filtering out spikes that are shorter than (Prop_Seg + Phase_Seg1).  
Apart from noise spikes, most synchronisations are caused by arbitration. All nodes  
synchronise “hard” on the edge transmitted by the “leading” transceiver that started  
transmitting first, but due to propagation delay times, they cannot become ideally  
synchronised. The “leading” transmitter does not necessarily win the arbitration, therefore the  
receivers have to synchronise themselves to different transmitters that subsequently “take the  
lead” and that are differently synchronised to the previously “leading” transmitter. The same  
happens at the acknowledge field, where the transmitter and some of the receivers will have to  
synchronise to that receiver that “takes the lead” in the transmission of the dominant  
acknowledge bit.  
Synchronisations after the end of the arbitration will be caused by oscillator tolerance, when  
the differences in the oscillator’s clock periods of transmitter and receivers sum up during the  
time between Synchronisations (at most ten bits). These summarized differences may not be  
longer than the SJW, limiting the oscillator’s tolerance range.  
The examples in figure 11 show how the Phase Buffer Segments are used to compensate for  
phase errors. There are three drawings of each two consecutive bit timings. The upper  
drawing shows the synchronisation on a “late” edge, the lower drawing shows the  
synchronisation on an “early” edge, and the middle drawing is the reference without  
synchronisation.  
recessive  
dominant  
late” Edge  
Rx-Input  
Sample-Point  
Sample-Point  
Sample-Point  
Sample-Point  
Sample-Point  
Sample-Point  
recessive  
dominant  
early” Edge  
Prop_Seg Phase_Seg1  
Rx-Input  
Sync_Seg  
Phase_Seg2  
Figure 11: Synchronisation on “late” and “early” Edges  
BOSCH  
- 48/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
In the first example an edge from recessive to dominant occurs at the end of Prop_Seg. The  
edge is “late” since it occurs after the Sync_Seg. Reacting to the “late” edge, Phase_Seg1 is  
lengthened so that the distance from the edge to the Sample Point is the same as it would  
have been from the Sync_Seg to the Sample Point if no edge had occurred. The phase error  
of this “late” edge is less than SJW, so it is fully compensated and the edge from dominant to  
recessive at the end of the bit, which is one nominal bit time long, occurs in the Sync_Seg.  
In the second example an edge from recessive to dominant occurs during Phase_Seg2. The  
edge is “early” since it occurs before a Sync_Seg. Reacting to the “early” edge, Phase_Seg2  
is shortened and Sync_Seg is omitted, so that the distance from the edge to the Sample Point  
is the same as it would have been from an Sync_Seg to the Sample Point if no edge had  
occurred. As in the previous example, the magnitude of this “early” edge’s phase error is less  
than SJW, so it is fully compensated.  
The Phase Buffer Segments are lengthened or shortened temporarily only; at the next bit time,  
the segments return to their nominal programmed values.  
In these examples, the bit timing is seen from the point of view of the CAN implementation’s  
state machine, where the bit time starts and ends at the Sample Points. The state machine  
omits Sync_Seg when synchronising on an “early” edge because it cannot subsequently  
redefine that time quantum of Phase_Seg2 where the edge occurs to be the Sync_Seg.  
The examples in figure 12 show how short dominant noise spikes are filtered by  
synchronisations. In both examples the spike starts at the end of Prop_Seg and has the length  
of (Prop_Seg + Phase_Seg1).  
In the first example, the Synchronisation Jump Width is greater than or equal to the phase  
error of the spike’s edge from recessive to dominant. Therefore the Sample Point is shifted  
after the end of the spike; a recessive bus level is sampled.  
In the second example, SJW is shorter than the phase error, so the Sample Point cannot be  
shifted far enough; the dominant spike is sampled as actual bus level.  
recessive  
dominant  
Spike  
Rx-Input  
Sample-Point  
Sample-Point  
SJW Phase Error  
recessive  
dominant  
Spike  
Rx-Input  
Sample-Point  
Sample-Point  
SJW < Phase Error  
Sync_Seg  
Prop_Seg  
Phase_Seg1  
Phase_Seg2  
Figure 12: Filtering of Short Dominant Spikes  
BOSCH  
- 49/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
4.2.1.4 Oscillator Tolerance Range  
The oscillator tolerance range was increased when the CAN protocol was developed from  
version 1.1 to version 1.2 (version 1.0 was never implemented in silicon). The option to  
synchronise on edges from dominant to recessive became obsolete, only edges from  
recessive to dominant are considered for synchronisation. The only CAN controllers to  
implement protocol version 1.1 have been Intel 82526 and Philips 82C200, both are  
superseded by successor products. The protocol update to version 2.0 (A and B) had no  
influence on the oscillator tolerance.  
The tolerance range df for an oscillator’s frequency f  
around the nominal frequency f  
nom  
osc  
with (1 df) • fnom fosc ≤ (1 + df) • fnomdepends on the proportions of Phase_Seg1, Phase_Seg2,  
SJW, and the bit time. The maximum tolerance df is the defined by two conditions (both shall  
be met):  
min(Phase_Seg1, Phase_Seg2)  
2 • (13 bit_time Phase_Seg2)  
---------------------------------------------------------------------------------------  
I: df ≤  
II: df ≤  
SJW  
--------------------------------  
20 bit_time  
It has to be considered that SJW may not be larger than the smaller of the Phase Buffer  
Segments and that the Propagation Time Segment limits that part of the bit time that may be  
used for the Phase Buffer Segments.  
The combination Prop_Seg = 1 and Phase_Seg1 = Phase_Seg2 = SJW = 4 allows the  
largest possible oscillator tolerance of 1.58%. This combination with a Propagation Time  
Segment of only 10% of the bit time is not suitable for short bit times; it can be used for bit  
rates of up to 125 kBit/s (bit time = 8 µs) with a bus length of 40 m.  
4.2.1.5 Configuration of the CAN Protocol Controller  
In most CAN implementations and also in the TTCAN, the bit timing configuration is  
programmed in two register bytes. The sum of Prop_Seg and Phase_Seg1 (as TSEG1) is  
combined with Phase_Seg2 (as TSEG2) in one byte, SJW and BRP are combined in the other  
Configuration (BRP)  
Scaled_Clock (tq)  
System Clock  
Baudrate_  
Prescaler  
Control  
Status  
Sample_Point  
Sampled_Bit  
Sync_Mode  
Receive_Data  
Bit  
Timing  
Logic  
Bit_to_send  
Bus_Off  
Received_Data_Bit  
Send_Message  
Transmit_Data  
Control  
Shift-Register  
Next_Data_Bit  
Received_Message  
Configuration (TSEG1, TSEG2, SJW)  
Figure 13: Structure of the CAN Core’s CAN Protocol Controller  
BOSCH  
- 50/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
In these bit timing registers, the four components TSEG1, TSEG2, SJW, and BRP have to be  
programmed to a numerical value that is one less than its functional value; so instead of  
values in the range of [1n], values in the range of [0n-1] are programmed. That way, e.g.  
SJW (functional range of [14]) is represented by only two bits.  
Therefore the length of the bit time is (programmed values) [TSEG1 + TSEG2 + 3] t or  
q
(functional values) [Sync_Seg + Prop_Seg + Phase_Seg1 + Phase_Seg2] t .  
q
The data in the bit timing registers are the configuration input of the CAN protocol controller.  
The Baud Rate Prescaler (configured by BRP) defines the length of the time quantum, the  
basic time unit of the bit time; the Bit Timing Logic (configured by TSEG1, TSEG2, and SJW)  
defines the number of time quanta in the bit time.  
The processing of the bit time, the calculation of the position of the Sample Point, and  
occasional synchronisations are controlled by the BTL state machine, which is evaluated once  
each time quantum. The rest of the CAN protocol controller, the Bit Stream Processor (BSP)  
state machine is evaluated once each bit time, at the Sample Point.  
The Shift Register serializes the messages to be sent and parallelizes received messages. Its  
loading and shifting is controlled by the BSP.  
The BSP translates messages into frames and vice versa. It generates and discards the  
enclosing fixed format bits, inserts and extracts stuff bits, calculates and checks the CRC  
code, performs the error management, and decides which type of synchronisation is to be  
used. It is evaluated at the Sample Point and processes the sampled bus input bit. The time  
after the Sample point that is needed to calculate the next bit to be sent (e.g. data bit, CRC bit,  
stuff bit, error flag, or idle) is called the Information Processing Time (IPT).  
The IPT is application specific but may not be longer than 2 t ; the TTCAN’s IPT is 0 t . Its  
q
q
length is the lower limit of the programmed length of Phase_Seg2. In case of a synchronisa-  
tion, Phase_Seg2 may be shortened to a value less than IPT, which does not affect bus timing.  
4.2.1.6 Calculation of the Bit Timing Parameters  
Usually, the calculation of the bit timing configuration starts with a desired bit rate or bit time.  
The resulting bit time (1/bit rate) must be an integer multiple of the system clock period.  
The bit time may consist of 4 to 25 time quanta, the length of the time quantum t is defined by  
q
the Baud Rate Prescaler with t = (Baud Rate Prescaler)/f . Several combinations may lead  
q
sys  
to the desired bit time, allowing iterations of the following steps.  
First part of the bit time to be defined is the Prop_Seg. Its length depends on the delay times  
measured in the system. A maximum bus length as well as a maximum node delay has to be  
defined for expandible CAN bus systems. The resulting time for Prop_Seg is converted into  
time quanta (rounded up to the nearest integer multiple of t ).  
q
The Sync_Seg is 1 t long (fixed), leaving (bit time – Prop_Seg – 1) t for the two Phase Buffer  
q
q
Segments. If the number of remaining t is even, the Phase Buffer Segments have the same  
q
length, Phase_Seg2 = Phase_Seg1, else Phase_Seg2 = Phase_Seg1 + 1.  
The minimum nominal length of Phase_Seg2 has to be regarded as well. Phase_Seg2 may  
not be shorter than the CAN controller’s Information Processing Time, which is, depending on  
the actual implementation, in the range of [02] t .  
q
The length of the Synchronisation Jump Width is set to its maximum value, which is the  
minimum of 4 and Phase_Seg1.  
The oscillator tolerance range necessary for the resulting configuration is calculated by the  
BOSCH  
- 51/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
If more than one configuration is possible, that configuration allowing the highest oscillator  
tolerance range should be chosen.  
CAN nodes with different system clocks require different configurations to come to the same  
bit rate. The calculation of the propagation time in the CAN network, based on the nodes with  
the longest delay times, is done once for the whole network.  
The CAN system’s oscillator tolerance range is limited by that node with the lowest tolerance  
range.  
The calculation may show that bus length or bit rate have to be decreased or that the oscillator  
frequencies’ stability has to be increased in order to find a protocol compliant configuration of  
the CAN bit timing.  
The resulting configuration is written into the Bit Timing Register:  
(Phase_Seg2-1)&(Phase_Seg1+Prop_Seg-1)&(SynchronisationJumpWidth-1)&(Prescaler-1)  
4.2.1.7 Example for Bit Timing at high Baudrate  
In this example, the frequency of CAN_CLK is 10 MHz, BRP is 0, the bit rate is 1 MBit/s.  
t
100 ns = t  
q
CAN_CLK  
delay of bus driver  
delay of receiver circuit  
delay of bus line (40m)  
50 ns  
30 ns  
220 ns  
t
t
t
t
t
600 ns = 6 • t  
100 ns = 1 • t  
Prop  
q
q
SJW  
700 ns = t  
+ t  
SJW  
TSeg1  
TSeg2  
Sync-Seg  
Prop  
200 ns = Information Processing Time + 1 • t  
q
100 ns = 1 • t  
q
bit time  
1000 ns = t  
+ t  
+ t  
TSeg1 TSeg2  
Sync-Seg  
min(PB1, PB2)  
2 × (13 × bit time PB2)  
---------------------------------------------------------------  
tolerance for CAN_CLK 0.39  
%
=
=
0.1µs  
-----------------------------------------------------------  
2 × (13 × 1µs 0.2µs)  
In this example, the concatenated bit time parameters are (2-1) &(7-1) &(1-1) &(1-1) , the Bit  
3
4
2
6
Timing Register is programmed to= 0x1600.  
BOSCH  
- 52/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
4.2.1.8 Example for Bit Timing at low Baudrate  
In this example, the frequency of CAN_CLK is 2 MHz, BRP is 1, the bit rate is 100 KBit/s.  
t
1
µs = 2 • t  
CAN_CLK  
q
delay of bus driver  
delay of receiver circuit  
delay of bus line (40m)  
200 ns  
80 ns  
220 ns  
t
t
t
t
t
1
4
5
4
1
µs = 1 • t  
Prop  
q
µs = 4 • t  
µs = t  
SJW  
q
+ t  
Prop  
TSeg1  
TSeg2  
Sync-Seg  
SJW  
µs = Information Processing Time + 3 • t  
q
µs = 1 • t  
q
bit time  
10 µs = t  
+ t  
+ t  
TSeg1 TSeg2  
Sync-Seg  
min(PB1, PB2)  
2 × (13 × bit time PB2)  
tolerance for CAN_CLK 1.58  
%
=
=
----------------------------------------------------------------  
4µs  
---------------------------------------------------------  
2 × (13 × 10µs 4µs)  
In this example, the concatenated bit time parameters are (4-1) &(5-1) &(4-1) &(2-1) , the Bit  
3
4
2
6
Timing Register is programmed to= 0x34C1.  
4.2.2 Configuration of the Message Memory  
The whole Message Memory has to be configured before the end of the initialisation, but is  
also possible to change the configuration of Message Objects during CAN communication.  
The CAN software driver library should offer subroutines that:  
Transfer a complete message structure into a Message Object. (Configuration)  
Transfer the data bytes of a message into a Message Object and set TxRqst and NewDat.  
(Start a new transmission)  
Get the data bytes of a message from a Message Object and clear NewDat (and IntPnd).  
(Read received data)  
Get the complete message from a Message Object and clear NewDat (and IntPnd).  
(Read a received message, including identifier, from a Message Object with UMask = ‘1’)  
Parameters of the subroutines are the Message Number and a pointer to a complete  
message structure or to the data bytes of a message structure.  
Two methods are possible to assign the IFx Interface Register sets to these subroutines. In the  
first method, the tasks of the application program that may access the module are assorted in  
two groups. Each group is restricted to the use of one of the Interface Register sets. The tasks  
of one group may interrupt tasks of the other group, but not of the same group.  
In the second method, which may be a special case of the first method, there are only two  
tasks is the application program that access the module. A Read_Message task that uses  
IFC1 to get received messages (full messages or data bytes only) from the Message RAM and  
a Write_Message task that uses IFC2 to write messages to be transmitted (or to be  
configured) into the Message RAM. Both tasks may interrupt each other.  
The CAN communication may be controlled interrupt-driven or by polling. The module’s  
Interrupt Register points to Message Objects with IntPnd = ‘1’. It is updated even if the  
interrupt line to the CPU is disabled (IE = ‘0’).  
BOSCH  
- 53/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
The CPU may poll all MessageObject’s NewDat and TxRqst bits in parallel, in the New Data x  
Registers and in the Transmission Request x Registers. Polling is made easier if all Transmit  
Objects are grouped at the low numbers, all Receive Objects are grouped at the high  
numbers.  
The internal prioritisation of the Transmit Objects is controlled by their Message Number, so  
the most urgent message should be configured for the first Message Object.  
The acceptance filtering for received Data Frames or Remote Frames is done in ascending  
order of Message Objects, so a frame that has been accepted by one Message Object cannot  
be accepted by another Message Object with a higher Message Number. The last Message  
Object may be configured to accept any Data Frame or Remote Frame that was not accepted  
by any other Message Object, for nodes that need to log the complete message traffic on the  
CAN bus.  
It is not necessary to configure Transmit Objects for the transmission of Remote Frames.  
Setting TxRqst for a Receive Object will cause the transmission of a Remote Frame with the  
same identifier as the Data Frame for that this receive Object is configured.  
Received Remote Frames do not require a Receive Object, they will, if in the matching  
Transmit Object the RmtEn bit is set, trigger automatically the transmission of a Data Frame.  
4.2.2.1 Configuration of a Transmit Object for Data Frames  
Figure 14 shows how a Transmit Object should be initialised.  
MsgVal Arb Data Mask EoB Dir NewDat MsgLst RxIE TxIE IntPnd RmtEn TxRqst  
1
appl. appl. appl.  
1
1
0
0
0
appl.  
0
appl.  
0
Figure 14: Initialisation of a Transmit Object  
The Arbitration Registers (ID28-0 and Xtd bit) are given by the application. They define the  
identifier and type of the outgoing message. If an 11-bit Identifier (“Standard Frame”) is used  
(Xtd = ‘0’), it is programmed to ID28 - ID18, ID17 - ID0 can then be disregarded.  
The Data Registers (DLC3-0, Data0-7) are given by the application, TxRqst and RmtEn may  
not be set before the data is valid.  
If the TxIE bit is set, the IntPnd bit will be set after a successful transmission of the Message  
Object.  
If the RmtEn bit is set, a matching received Remote Frame will cause the TxRqst bit to be set;  
the Remote Frame will autonomously be answered by a Data Frame.  
The Mask Registers (Msk28-0, UMask, MXtd, and MDir bits) may be used (UMask=’1’) to  
allow groups of Remote Frames with similar identifiers to set the TxRqst bit. The Dir bit should  
not be masked. For details see section 4.1.3.2, handle with care. Identifier masking must be  
disabled (UMask = ‘0’) if no Remote Frames are allowed to set the TxRqst bit (RmtEn = ‘0’).  
4.2.2.2 Configuration of a Single Receive Object for Data Frames  
Figure 14 shows how a Receive Object should be initialised.  
MsgVal Arb Data Mask EoB Dir NewDat MsgLst RxIE TxIE IntPnd RmtEn TxRqst  
1
appl. appl. appl.  
1
0
0
0
appl.  
0
0
0
0
Figure 15: Initialisation of a single Receive Object  
BOSCH  
- 54/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
The Arbitration Registers (ID28-0 and Xtd bit) are given by the application. They define the  
identifier and type of accepted received messages. If an 11-bit Identifier (“Standard Frame”) is  
used (Xtd = ‘0’), it is programmed to ID28 - ID18, ID17 - ID0 can then be disregarded. When a  
Data Frame with an 11-bit Identifier is received, ID17 - ID0 will be set to ‘0’.  
The Data Length Code (DLC3-0) is given by the application. When the Message Handler  
stores a Data Frame in the Message Object, it will store the received Data Length Code and  
eight data bytes. If the Data Length Code is less than 8, the remaining bytes of the Message  
Object will be overwritten by non specified values.  
The Mask Registers (Msk28-0, UMask, MXtd, and MDir bits) may be used (UMask=’1’) to  
allow groups of Data Frames with similar identifiers to be accepted. The Dir bit should not be  
masked in typical applications. For details see section 4.1.3.1. If some bits of the Mask  
Register are set to “don’t care”, the corresponding bits of the Arbitration Register will be  
overwritten by the bits of the stored Data Frame.  
If the RxIE bit is set, the IntPnd bit will be set when a received Data Frame is accepted and  
stored in the Message Object.  
If the TxRqst bit is set, this will cause the transmission of a Remote Frame with the same  
identifier as actually stored in the Arbitration Register. The content of the Arbitration Register  
may change if the Mask Registers are used (UMask=’1’) for acceptance filtering.  
4.2.2.3 Configuration of a FIFO Buffer  
With the exception of the EoB bit, the configuration of Receive Objects belonging to a FIFO  
Buffer is the same as the configuration of a (single) Receive Object, see section 4.2.2.2.  
To concatenate two or more Message Objects into a FIFO Buffer, the identifiers and masks (if  
used) of these Message Objects have to be programmed to matching values. Due to the  
implicit priority of the Message Objects, the Message Object with the lowest number will be  
the first Message Object of the FIFO Buffer. The EoB bit of all Message Objects of a FIFO  
Buffer except the last one have to be programmed to zero. The EoB bits of the last Message  
Object of a FIFO Buffer is set to one, configuring it as the End of the Block.  
4.2.2.4 Configuration of a Single Receive Object for Remote Frames  
Figure 14 shows how a Receive Object should be initialised.  
MsgVal Arb Data Mask EoB Dir NewDat MsgLst RxIE TxIE IntPnd RmtEn TxRqst  
1
appl. appl. appl.  
1
1
0
0
appl.  
0
0
0
0
Figure 16: Initialisation of a single Receive Object  
Receive Objects for Remote Frames may be used to monitor Remote Frames on the CAN bus.  
The Remote Frame stored in the Receive Object will not trigger the transmission of a Data  
Frame. Receive Objects for Remote Frames may be expanded to a FIFO buffer.  
UMask must be set to ‘1’. The Mask Registers (Msk28-0, UMask, MXtd, and MDir bits) may  
be set to “must-match” or to “don’t care”, to allow groups of Remote Frames with similar  
identifiers to be accepted. The Dir bit should not be masked in typical applications. For details  
The Arbitration Registers (ID28-0 and Xtd bit) may be given by the application. They define  
the identifier and type of accepted received Remote Frames. If some bits of the Mask Register  
are set to “don’t care”, the corresponding bits of the Arbitration Register will be overwritten by  
the bits of the stored Remote Frame. If an 11-bit Identifier (“Standard Frame”) is used (Xtd =  
BOSCH  
- 55/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
‘0’), it is programmed to ID28 - ID18, ID17 - ID0 can then be disregarded. When a Remote  
Frame with an 11-bit Identifier is received, ID17 - ID0 will be set to ‘0’.  
The Data Length Code (DLC3-0) may be given by the application. When the Message Handler  
stores a Remote Frame in the Message Object, it will store the received Data Length Code.  
The data bytes of the Message Object will remain unchanged.  
If the RxIE bit is set, the IntPnd bit will be set when a received Remote Frame is accepted and  
stored in the Message Object.  
4.3 CAN Communication  
When the initialisation is finished, the TTCAN module synchronises itself to the traffic on the  
CAN bus. It does an acceptance filtering on received messages and stored those frames that  
are accepted into the designated Message Objects. The application program has to update  
the data of the messages to be transmitted and has to enable and request their transmission.  
The transmission is requested automatically when a matching Remote Frame is received or in  
time triggered communication.  
The application program reads messages that are received and accepted. Messages that are  
not read before the next messages is accepted for the same Message Object will be  
overwritten. The Message Objects of a FIFO buffer need to be read and cleared before the  
next batch of messages can be stored. Depending on the configuration, the messages may be  
read interrupt-driven, after polling of NewDat, or time triggered.  
If one of the Interface Register sets is used only for reading of received messages its  
Command Mask Register may be kept constant at 0x7F, meaning that always the whole  
Message Object is transferred into the Interface Register set; NewDat and IntPnd are reset.  
To update the data bytes of a message to be transmitted, the Command Mask Register should  
be set to 0x87 (all transmit messages in C_CAN emulation mode or event triggered message  
in arbitrating time window) or to 0x83 (time triggered message in exclusive time window).  
Note : After the update of the Transmit Object, the Interface Register set will contain a copy of the  
actual contents of the object, including the part that had not been updated.  
4.3.1 Handling of Interrupts  
The TTCAN module provides several interrupt sources which share a common interrupt line.  
The common interrupt line to the CPU can be enabled/disabled by IE. The module’s interrupt  
sources can be enabled/disabled separately, by the TT Interrupt Enable Register, by the CAN  
Control Register bits SIE and EIE, or by the RxIE and TxIE bits of each Message Object. The  
source of a pending interrupt is shown by the CAN Interrupt Register.  
The Status Interrupt and the TTCAN Interrupt have the highest priority. Among the message  
interrupts, the Message Object’ s interrupt priority decreases with increasing Message  
Number.  
If several interrupts are pending, the CAN Interrupt Register will point to the pending interrupt  
with the highest priority, disregarding their chronological order. An interrupt remains pending  
until the CPU has cleared it.  
A message interrupt is cleared by clearing the Message Object’s IntPnd bit. The Status  
Interrupt is cleared by reading the Status Register. The TTCAN Interrupt is cleared by reading  
the TT Interrupt Vector Register.  
BOSCH  
- 56/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
The interrupt identifier IntId in the Interrupt Register indicates the cause of the interrupt. When  
no interrupt is pending, the register will hold the value zero. If the value of the Interrupt  
Register is different from zero, then there is an interrupt pending and, if IE is set, the interrupt  
line to the CPU is active. The interrupt line remains active until the Interrupt Register is back to  
value zero (the cause of the interrupt is reset) or until IE is reset.  
The value 0x4000 or 0xC000 indicates that an interrupt is pending in the TT Interrupt Vector  
Register and is enabled in the TT Interrupt Enable Register.  
The value 0x8000 or 0xC000 indicates that an interrupt is pending because the CAN Core has  
updated (not necessarily changed) the Status Register (Error Interrupt or Status Interrupt).  
This interrupt has the highest priority. The CPU can update (reset) the status bits RxOk, TxOk  
and LEC, but a write access of the CPU to the Status Register can never generate or reset an  
interrupt.  
All other values indicate that the source of the interrupt is one of the Message Objects, IntId  
points to the pending message interrupt with the highest interrupt priority.  
The CPU controls whether a change of the Status Register may cause an interrupt (bits EIE  
and SIE in the CAN Control Register) and whether the interrupt line becomes active when the  
Interrupt Register is different from zero (bit IE in the CAN Control Register). The Interrupt  
Register will be updated even when IE is reset.  
The Last Error Code LEC in the Status Register allows the interrupt service routine to analyse  
the CAN bus errors. AckError e.g. indicates that no other node is active on the CAN bus.  
The CPU has two possibilities to follow the source of a message interrupt. First it can follow  
the IntId in the Interrupt Register and second it can poll the Interrupt Pending Register (see  
An interrupt service routine reading the message that is the source of the interrupt may read  
the message and reset the Message Object’s IntPnd at the same time (bit ClrIntPnd in the  
Command Mask Register). When IntPnd is cleared, the Interrupt Register will point to the next  
Message Object with a pending interrupt.  
4.3.2 Updating a Transmit Object  
The CPU may update the data bytes of a Transmit Object any time via the IFx Interface  
Registers, neither MsgVal nor TxRqst have to be reset before the update.  
Even if only a part of the data bytes are to be updated, all four bytes of the corresponding IFx  
Data A Register or IFx Data B Register have to be valid before the content of that register is  
transferred to the Message Object. Either the CPU has to write all four bytes into the IFx Data  
Register or the Message Object is transferred to the IFx Data Register before the CPU writes  
the new data bytes.  
When only the (eight) data bytes are updated, first 0x0087 is written to the Command Mask  
Register and then the number of the Message Object is written to the Command Request  
Register, concurrently updating the data bytes and setting TxRqst with NewDat.  
To prevent the reset of TxRqst at the end of a transmission that may already be in progress  
while the data is updated, NewDat has to be set together with TxRqst in event driven CAN  
When NewDat is set together with TxRqst, NewDat will be reset as soon as the new  
transmission has started.  
BOSCH  
- 57/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
4.3.3 Changing a Transmit Object  
In an application for that the number of Message Objects in the TTCAN module is not  
sufficient, the Transmit Objects may be managed dynamically. The CPU writes the whole  
message (Arbitration, Control, and Data) into the Interface Register. The Command Mask  
Register is set to 0x00B7 for the transfer of the contents into the designated Message Object.  
Neither MsgVal nor TxRqst have to be reset before this operation.  
If a previously requested transmission of that Message Object is not completed but already in  
progress, it will be continued; it will however not be repeated if it is disturbed.  
4.3.4 Reading Received Messages  
The CPU may read a received message any time via the IFx Interface Registers, the data  
consistency is guaranteed by the Message Handler state machine.  
Typically the CPU will write first 0x007F to the Command Mask Register and then the number  
of the Message Object to the Command Request Register. That combination will transfer the  
whole received message from the Message RAM into the Message Buffer Register.  
Additionally, the bits NewDat and IntPnd are cleared in the Message RAM (not in the  
Message Buffer). The values of these bits in the Message Control Register always reflect the  
status before resetting the bits.  
If the Message Object uses masks for acceptance filtering, the arbitration bits show which of  
the different matching messages has been received.  
The actual value of NewDat shows whether a new message has been received since last time  
this Message Object was read. The actual value of MsgLst shows whether more than one  
message has been received since last time this Message Object was read. MsgLst will not be  
automatically reset.  
4.3.5 Requesting New Data for a Receive Object  
By means of a Remote Frame, the CPU may request another CAN node to provide new data  
for a receive object. Setting the TxRqst bit of a receive object will cause the transmission of a  
Remote Frame with the receive object’s identifier. This Remote Frame triggers the other CAN  
node to start the transmission of the matching Data Frame. If the matching Data Frame is  
received before the Remote Frame could be transmitted, the TxRqst bit is automatically reset.  
Setting the TxRqst bit without changing the contents of a Message Object requires the value  
0x0084 in the Command Mask Register.  
4.3.6 Reading from a FIFO Buffer  
Several messages may be accumulated in a set of Message Objects which are concatenated  
to form a FIFO Buffer before the application program is required (in order to avoid the loss of  
data) to empty the buffer. A FIFO Buffer of length N will store the first (N-1) and the last  
received message since last time it was cleared.  
A FIFO Buffer is cleared by reading and resetting the NewDat bits of all its Message Objects,  
starting at the FIFO Object with the lowest message number. This should be done in a  
subroutine following the example shown in figure 17.  
Reading from a FIFO Buffer Message Object and resetting its NewDat bit is handled the same  
way as reading from a single Message Object.  
BOSCH  
- 58/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
START  
Message Interrupt  
Read Interrupt Pointer  
case Interrupt Pointer  
else  
0x8000h  
0x0000h  
END  
Status Change  
Interrupt Handling  
IFx Command Mask = 0x007F  
MessageNum = Interrupt Pointer  
Write MessageNum to IFx Command Request  
(Transfer Message to IFx Registers,  
Clear NewDat and IntPnd)  
Read IFx Message Control  
No  
NewDat = 1  
Yes  
Read Data from IFx Data A,B  
Yes  
EoB = 1  
No  
MessageNum = MessageNum + 1  
Figure 17: CPU Handling of a FIFO Buffer (Interrupt Driven)  
BOSCH  
- 59/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
5. TTCAN Application  
5.1 TTCAN Configuration  
The TTCAN’s default operating mode after hardware reset is Standard CAN Communication  
without time triggers. The TTMode has to be switched into Configuration Mode before the  
timing and system matrix setup can be written into the TTCAN’s configuration registers. It is  
required that both Init and CCE are set before TTMode can be changed.  
5.1.1 TTCAN Timing  
The Network Time Unit (NTU) is the unit in which all times are measured. NTU is a constant of  
the whole network and is defined a priori by the network system designer. In TTCAN Level 1  
NTU is the nominal CAN bit time. In TTCAN Level 2 NTU is a fraction of the physical second.  
The length of the NTU is defined by the Time Unit Ratio, TUR. TUR is the ratio between the  
length of an NTU and the length of the FSE specific basic time unit, the system clock period.  
In the TTCAN, TUR = NumAct/DenomCfg is in principle a non-integer number. NTU is the  
time base for the Local Time, the integer part of Local Time (16-bit-value) will be incremented  
once each NTU. Cycle Time and Global Time are both derived from Local Time. The fractional  
part (3-bit-value) of Local Time, Cycle Time, and Global Time is not readable.  
The default value of NumAct is NumCfg, but in nodes that are not the current time master,  
NumAct may be adapted during operation in a TTCAN Level 2 network. The default length of  
the NTU is given by the formula NTU = (NumCfg/DenomCfg) System Clock Period or by the  
formula (NumCfg • System Clock Period) = (DenomCfg • NTU).  
In a TTCAN Level 2 network, the nodes that are not the current time master will adapt their  
NumAct within a specified limit in order to compensate for clock drift between their local clock  
and the time master’s clock. The Synchronisation Deviation SD = |NumCfg-NumAct| is  
limited by the Synchronisation Deviation Limit SDL, which is configured by its dual logarithm  
(ldSDL+5)  
ldSDL (SDL=2  
) and should not exceed the clock tolerance given by the CAN bit  
timing configuration. SD is calculated at each new Basic Cycle; when the calculated NumAct  
deviates by more than SDL from NumCfg, or if the Disc_Bit in the Reference Message is set,  
the drift compensation is suspended and the GTE interrupt is activated, or in case of the  
Disc_Bit the Dis interrupt is activated.  
There is no drift compensation in TTCAN Level 1, NumAct will always be NumCfg.  
The TUR Numerator Configuration NumCfg is an 18-bit number, its bits NumCfg[150] can  
be programmed in the range 0x0000-0xFFFF. NumCfg[1716] is hard wired to 0b01, so  
when the number 0xnnnn is written to NumCfg[150] in the TUR Numerator Configuration  
Low register, NumAct starts with the value 0x10000+0x0nnnn = 0x1nnnn.  
The TUR Denominator Configuration DenomCfg is a 14-bit number, 0x0000 is an illegal value  
for DenomCfg. DenomCfg[130] may be programmed in the range 0x0001-0x3FFF.  
DenomCfg is set to 0x1000 and NumCfg is set to 0x10000 at hardware reset, resulting in an  
NTU consisting of 16 System Clock Periods. In Level1, NumCfg must be 4•DenomCfg. In  
TTCAN Level2, NumCfg must be 8 • DenomCfg to allow the 3-bit resolution for the internal  
fractional part of the NTU.  
The clock calibration process in TTCAN Level 2 can adapt NumAct in the range of the  
(ldSDL+5)  
(ldSDL+5)  
Synchronisation Deviation Limit SDL [NumCfg-2  
NumCfg+2  
]. NumCfg  
should be programmed to the largest applicable numerical value in order to achieve the best  
accuracy in the calculation of NumAct. TUR configuration examples are shown in Figure 18.  
manual_ttcan_application.fm  
BOSCH  
- 60/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
TUR  
8
10  
24  
50  
510 125000 32.5 100/12 529/17  
0x1FFF8 0x1FFFE 0x1FFF8 0x1FFEA 0x1FFFE 0x1E848 0x1FFE0 0x19000 0x10880  
NumCfg  
0x3FFF 0x3333 0x1555 0x0A3D 0x0101 0x0001 0x0FC0 0x3000 0x0880  
DenomCfg  
Figure 18: TUR configuration examples  
The TTCAN module provides a watchdog to verity the function of the application program. The  
host has to serve this watchdog regularly, else all CAN bus activity is stopped. The Application  
Watchdog Limit AppWdL (range 0x00 to 0xFF) specifies the maximum number of 256•NTUs  
between two times the watchdog is served. The Application Watchdog Limit may be written  
during Configuration Mode, its default value is 0x01. The Watchdog is served by reading the  
(high byte of the) Application Watchdog Limit register. The MSB of this register shows whether  
the watchdog has been served in time.  
After hardware reset, the length of the NTU is 16 System Clock Periods, but the Local Time  
and the Watchdog Timer are not started before either the Init bit in the CAN Control register is  
reset or the ELT bit in the Clock Control register is set. ELT may not be set before the NTU is  
configured, setting ELT to ‘1’ also locks the write access to the TUR Denominator  
Configuration Register.  
For software development, the watchdog may be disabled by setting the WdOff bit in the Test  
register and setting AppWdL to 0x00, see chapter 2.3.4.2.  
5.1.2 Message Scheduling  
TM in the Operation Mode register controls whether the TTCAN module operates as a  
potential Time Master or exclusively as a Time Slave. If it is a potential Time Master,  
MPr[20] defines its master priority, 0 giving the highest and 7 giving the lowest priority.  
There may not be two nodes in the network using the same master priority, since the master  
priority is identical to the three LSBs of the Reference Message Identifier. MPr is not relevant  
for Time Slaves.  
The Initial Reference Trigger Offset Init_Ref_Offset is a 7-bit-value that defines (in NTUs)  
how long a backup Time Master waits before it starts the transmission of a Reference  
Message when a Reference Message is expected but the bus remains idle. The  
recommended value for Init_Ref_Offset is MPr multiplied with a factor, the factor depending  
on the expected clock drift between the potential Time Masters in the network. The sequential  
order of the backup Time Masters, when one of them starts the Reference Message in case  
the current Time Master fails, should correspond to their master priority, even with maximum  
clock drift.  
L2 decides whether the node operates in TTCAN Level 1 or in TTCAN Level 2. In one  
network, all potential Time Masters have to operate in the same level. Time Slaves may  
operate on Level 1 in a Level 2 network, but not vice versa.  
EECS enables the external clock synchronisation, allowing the application program of the  
current Time Master to update the TUR configuration during Time Triggered Operation, to  
adapt the clock speed and (in Level 2 only) the Global Clock phase to an external reference.  
The configuration of the TTCAN Operation Mode TTMode is the last step in the setup, since  
the configuration registers are writable in “Configuration Mode” only. In the TTMode “Event  
driven CAN Communication”, the TTCAN module operates according to ISO 11898-1, without  
Time Triggers. In the TTMode “Strictly Time Triggered Operation”, the TTCAN module  
BOSCH  
- 61/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
operates according to ISO 11898-4, but without the possibility to synchronise the Basic Cycles  
to external events, the Next_is_Gap bit in the Reference Message is ignored. In the TTMode  
“Event Synchronised Time Triggered Operation”, the TTCAN module operates according to  
ISO 11898-4, including the event synchronised start of a Basic Cycle.  
ETT in the Matrix Limits registers specifies the number of Expected Tx_Triggers in the System  
Matrix. This is the sum of the Tx_Triggers for Exclusive, single Arbitrating and Merged  
Arbitrating Windows, excluding the Tx_Ref_Triggers. Note that this is usually not the number  
of Tx_Triggers in the Trigger Memory; the number of Basic Cycles in the System Matrix and  
the Trigger’s Repeat Factors have to be taken into account. An inaccurate configuration of ETT  
will result in either a Tx_Underflow (Error level 1) or in a Tx_Overflow (Error level 2).  
CCM specifies the number of the last Basic Cycle in the System Matrix. The counting of Basic  
Cycles starts at 0, so in a System Matrix consisting of 8 Basic Cycles CCM would be 7. CCM  
is ignored by Time Slaves, a receiver of a Reference Message considers the received  
Cycle_Count as the valid Cycle_Count for the actual Basic Cycle.  
RDLC specifies the Data Length Code of the Reference Messages transmitted by a potential  
Time Master. It has to be at least 0x1 for TTCAN Level 1 and 0x4 for TTCAN Level 2.  
TEW specifies the length of the Tx_Enable Window in NTUs. The Tx_Enable Window is that  
period of time at the beginning of a Time Window where a transmission may be started. If a  
transmission of a message cannot be started inside the Tx_Enable Window, because of e.g.  
a slight overlap from the previous Time Window’s message, the transmission cannot be  
started in that Time Window at all. TEW has to be chosen with respect to the network’s  
synchronisation quality and with respect to the relation between the length of the Time  
Windows and the length of the messages.  
Which interrupt sources to enable in the TT Interrupt Enable register is application specific.  
Write accesses to the Interrupt Enable register are not restricted to the Configuration Mode.  
5.1.3 Trigger Memory  
The Trigger Memory holds place for up to 32 Triggers. The Trigger information consists of  
Time_Mark, Message Number, Cycle_Code, and Trigger Type.  
The Time_Mark defines at which Cycle Time a the Trigger becomes active.  
Message Number and Cycle_Code are defined for all Triggers, but they are ignored for the  
Trigger Types Tx_Ref_Trigger, Tx_Ref_Trigger_Gap, Watch_Trigger, Watch_Trigger_Gap, and  
EndOfList. The Reference Message is linked to Message Object Number 1 by hardware and  
neither the Watch_Triggers nor the EndOfList Trigger are linked to any Message Object.  
Eight different Trigger Types are available :  
Tx_Ref_Trigger and Tx_Ref_Trigger_Gap cause the transmission of a Reference Message by  
a Time Master. A Configuration Error (Error level 3) is detected when a Time Slave encounters  
a Tx_Ref_Trigger(_Gap) in its Trigger Memory. Tx_Ref_Trigger_Gap is only used for the Event  
Synchronised Time Triggered Operation mode. In that mode, Tx_Ref_Trigger is ignored when  
the TTCAN Synchronisation State SyncSt is In_Gap.  
Watch_Trigger and Watch_Trigger_Gap check for missing Reference Messages. They are  
used by both Time Masters and Time Slaves. Watch_Trigger_Gap is only used for the Event  
Synchronised Time Triggered Operation mode. In that mode, Watch_Trigger is ignored when  
the TTCAN Synchronisation State SyncSt is In_Gap.  
Tx_Trigger_Single and Tx_Trigger_Merged both cause the start of a transmission, they define  
the start of Time Windows. Tx_Trigger_Single may be used for Exclusive Time Windows and  
BOSCH  
- 62/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
for Arbitrating Time Windows, Tx_Trigger_Merged may be used only for Merged Arbitrating  
Time Windows. The last Tx_Trigger of a Merged Arbitrating Time Window must be of the type  
Tx_Trigger_Single. A Configuration Error (Error level 3) is detected when a Trigger of the type  
Tx_Trigger_Merged is followed by any other Trigger than one of the type Tx_Trigger_Single or  
Tx_Trigger_Merged. Several Tx_Triggers may be defined for the same Message Object.  
Depending on their Cycle_Code, they may be ignored in some Basic Cycles. The Cycle_Code  
has to be considered when ETT is calculated.  
Rx_Trigger is used to check for the reception of periodic messages in Exclusive Time  
Windows. The Time Mark of an Rx_Trigger shall be placed after the end of that message’s  
transmission, independent of Time Window boundaries. Several Rx_Triggers may be defined  
for the same Message Object. Depending on their Cycle_Code, they may be ignored in some  
Basic Cycles.  
EndOfList is an illegal Trigger type, a Configuration Error (Error level 3) is detected when an  
EndOfList Trigger is encountered in the Trigger Memory.  
The Trigger information is written into the Trigger Memory using the IF1 Data B1 and IF1 Data  
B2 registers and the Trigger Memory Access Register, similar to the configuration of Message  
Objects. On each transfer, 32 bits are loaded either from the IF1 Data B1 and B2 Registers to  
the selected Trigger Memory word or vice versa. Write access to the Trigger Memory is locked  
when the Configuration Mode is left.  
The Triggers in the Trigger Memory have to be sorted by their Time_Marks, the Trigger with  
the lowest Time_Mark is written to the first Trigger Memory word.  
Note : If the Reference Message is n NTU long, then a Trigger with a Time_Mark<n will never become  
active and will be treated as a Configuration Error.  
Starting point of the Cycle Time is the Sample Point of the Reference Message’s Start of  
Frame bit. The next Reference Message is requested when Cycle Time reaches the  
Tx_Ref_Trigger’s Time_Mark. The CAN_Core reacts on the transmission request at the next  
Sample Point. A new Sync_Mark is captured at the Start of Frame bit, but the Cycle Time is  
incremented until the Reference Message is successfully transmitted (or received) and the  
Sync_Mark is taken as the new Ref_Mark. At that point of time, Cycle Time is restarted. As a  
consequence, Cycle Time can never (with the exception of initialisation) be seen at a value<n,  
with n being the length of the Reference Message measured in NTU. The length of the Basic  
Cycle is Tx_Ref_Trigger’s Time_Mark+(1NTU+1CAN bit time).  
The Trigger List will be different for all nodes in the TTCAN network, each node knows only the  
Tx_Triggers for its own transmit messages, the Rx_Triggers for those receive messages that  
are processed by this node, and the Triggers concerning the Reference Messages.  
The following restrictions exist for the node’s Trigger List :  
There may not be two Triggers that are active at the same Cycle Time and Cycle_Count, but  
Triggers that are active in different Basic Cycles may share the same Time_Mark.  
Rx_Triggers may not be placed inside Merged Arbitration Windows or inside the Tx_Enable  
Windows of other Tx_Triggers, but they may be placed after the Tx_Ref_Trigger.  
Triggers that are placed after the Watch_Trigger (or after the Watch_Trigger_Gap when  
SyncSt is In_Gap) will never become active, the Watch_Triggers themselves will not become  
active when the Reference Messages are transmitted on time.  
All unused Trigger Memory words (after the Watch_Trigger or after the Watch_Trigger_Gap  
when SyncSt is In_Gap) must be set to Trigger Type EndOfList.  
BOSCH  
- 63/77 -  
11.11.02  
 
User’s Manual  
TTCAN  
Revision 1.6  
A typical Trigger List for a potential Time Master will begin with a number of Tx_Triggers and  
Rx_Triggers followed by the Tx_Ref_Trigger and the Watch_Trigger. For networks with Event  
Synchronised Time triggered Communication, this is followed by the Tx_Ref_Trigger_Gap and  
the Watch_Trigger_Gap. The Trigger List for a Time Slave will be the same but without the  
Tx_Ref_Trigger and the Tx_Ref_Trigger_Gap.  
At the beginning of each Basic Cycle, that is at each reception or transmission of a Reference  
Message, the Trigger List will be processed starting with the first Trigger Memory word. The  
FSE looks for the first Trigger with a Cycle_Code that matches the current Cycle_Count. The  
FSE waits until Cycle Time reaches the Trigger’s Time_Mark and activates the Trigger.  
Afterwards the FSE looks for the next Trigger in the list with a Cycle_Code that matches the  
current Cycle_Count.  
A Configuration Error is detected at the following conditions :  
When the FSE comes to a Trigger in the list with a Cycle_Code that matches the current  
Cycle_Count but with a Time_Mark that is less than Cycle Time.  
When the FSE comes to a Trigger in the list with a Cycle_Code that matches the current  
Cycle_Count but that is neither Tx_Trigger_Merged nor Tx_Trigger_Single and the previous  
active Trigger was a Tx_Trigger_Merged.  
When the FSE of a node with TM=‘0’ encounters a Tx_Ref_Trigger or a Tx_Ref_Trigger_Gap.  
When the Time_Mark of an Rx_Trigger is placed inside the Tx_Enable Window of a  
Tx_Trigger with a matching Cycle_Code or between a Tx_Trigger_Merged and another  
Tx_Trigger with a Cycle_Code matching the same Cycle_Count.  
When the Time_Mark of an Rx_Trigger is placed near the Time_Mark of a Tx_Ref_Trigger and  
the Ref_Trigger_Offset causes a reversal of their sequential order measured in Cycle Time.  
5.1.4 Message Objects  
The Message Status Count MSC of each Message Object has to be initialised to 0. It can only  
be written in “Configuration Mode”. The configuration of Receive Objects for “Time Triggered  
Communication” is the same as for “Event driven Communication”, see chapter 4.2.2. Some  
differences exist for the configuration of the Reference Message and of Transmit Objects:  
5.1.4.1 Reference Message  
The first Message Object is reserved for the transmission or reception of the Reference  
Message. When a Reference Message is transmitted, the last three bits of the Identifier, the  
DLC, and the first data byte (TTCAN Level 1) or the first three data bytes (TTCAN Level 2) will  
be provided by the FSE, the rest of the Reference Message is provided by the first Message  
Object. The first Message Object requires the following configuration: The Identifier and the  
Data Length Code of the Reference Message including IDE bit, MsgVal=‘1’, NewDat=‘1’,  
TxRqst=‘0’, UMask=‘1’, EoB=‘1’, Dir=‘1’, MDir=‘0’. When the Reference Message uses an  
Extended Identifier, Msk=0x1FFFFFF8, else Msk=0x1FE3FFFF. The MSC of the first  
Message Object will not be updated.  
5.1.4.2 Periodic Transmit Message  
The Message Objects for periodic transmit messages may not be managed dynamically, each  
Tx_Trigger in the Trigger Memory points to a particular Message Object containing a specific  
message. There may be more than one Tx_Trigger for a given Message Object, if that  
Message Object contains a message that is to be transmitted more than once in a Basic Cycle  
or Matrix Cycle. The configuration has to define MsgVal=‘1’, RmtEn=‘0’, TxRqst=‘0’,  
UMask=‘0’, EoB=‘1’, Dir=‘1’, MDir=‘0’, MSC=0, the identifier, the IDE bit, and the DLC.  
BOSCH  
- 64/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
TxRqst and RmtEn may never be set for a periodic transmit message. To enable the  
transmission of a periodic message inside an Exclusive Time Window, TxRqst has to be set to  
‘0’ and NewDat has to be set to ‘1’. The message will be transmitted each time its  
Tx_Trigger(s) become(s) active, neither TxRqst nor NewDat will be changed. MSC will be  
updated according to the success of the transmissions.  
The application program has to ensure that all data of the periodic transmit messages are  
valid before the time triggered communication is started.  
5.1.4.3 Event Driven Transmit Message  
The configuration of an event driven transmit message for the transmission inside an  
Arbitrating Time Window is the same as for “Event driven Communication”. The combination  
of TxRqst=‘0’ and NewDat=‘1 is illegal for an event driven transmit message.  
The Message Objects for event driven transmit messages may be managed dynamically,  
several messages with different identifiers may share the same Message Object.  
5.2 TTCAN Schedule Initialisation  
The synchronisation to the TTCAN message schedule starts when the Operation Mode is  
switched from Configuration Mode to either Strictly Time Triggered Operation or to Event  
Synchronised Time Triggered Operation. All nodes will start with Cycle Time=0 at the  
beginning of their Trigger List, SyncSt will be 0 (out of synchronisation), and no transmission  
will be enabled with the exception of the Reference Message. Nodes in mode Event  
Synchronised Time Triggered Operation will ignore Tx_Ref_Trigger and Watch_Trigger and  
will use instead Tx_Ref_Trigger_Gap and Watch_Trigger_Gap until the first Reference  
Message decides whether a Gap is active.  
5.2.1 Time Slaves  
After configuration, a Time Slave will ignore its Watch_Trigger and Watch_Trigger_Gap when it  
did not receive any message before reaching the Watch_Triggers. When it reaches  
Initial_Watch_Trigger (not part of the Trigger List, defined as maximum of Cycle Time), IWT in  
the Interrupt Vector register is set, the FSE is frozen, and the Cycle Time will become invalid,  
but the node will still be able to take part in CAN bus communication (to give acknowledge or  
to send error flags). The first received Reference Message will restart FSE and Cycle Time.  
When a Time Slave has received any message but the Reference Message before reaching  
the Watch_Triggers, it will assume a Fatal Error (Error Level 3), set WTr in the Interrupt Vector  
register, switch off its CAN bus output, and enter the Bus Monitoring Mode. In the Bus  
Monitoring Mode, it is still able to receive messages, but it cannot send any dominant bits and  
therefore cannot give acknowledge. The Fatal Error state can be left via a re-configuration.  
When no error is encountered during synchronisation, the first Reference Message will put  
SyncST to Synchronising and the second will put it (depending on its Next_is_Gap bit) into  
In_Schedule or In_Gap, enabling all Tx_Triggers and Rx_Triggers.  
5.2.2 Potential Time Masters  
After configuration, a Potential Time Master will start the transmission of a Reference  
Message when it reaches its Tx_Ref_Trigger (or its Tx_Ref_Trigger_Gap when in mode Event  
Synchronised Time Triggered Operation). It will ignore its Watch_Trigger and  
Watch_Trigger_Gap when it did not receive any message or transmit the Reference Message  
successfully before reaching the Watch_Triggers (assumed reason: All other nodes still in  
BOSCH  
- 65/77 -  
11.11.02  
 
       
User’s Manual  
TTCAN  
Revision 1.6  
reset or configuration, giving no acknowledge). When it reaches Initial_Watch_Trigger (not  
part of the Trigger List, defined as maximum of Cycle Time), the attempted transmission is  
aborted, IWT in the Interrupt Vector register is set, the FSE is frozen, and the Cycle Time will  
become invalid, but the node will still be able to take part in CAN bus communication (to give  
acknowledge or to send error flags). Resetting IWT will restart the FSE and Cycle Time, the  
FSE will not be restarted by the reception of a Reference Message.  
When a Potential Time Master reaches the Watch_Triggers after it has received any message  
but the Reference Message, it will assume a Fatal Error (Error Level 3), set WTr in the  
Interrupt Vector register, switch off its CAN bus output, and enter the Bus Monitoring Mode. In  
the Bus Monitoring Mode, it is still able to receive messages, but it cannot send any dominant  
bits (e.g. cannot give acknowledge). The Fatal Error state can be left via a re-configuration.  
When no error is encountered during initialisation, the first Reference Message will put  
SyncST to Synchronising and the second will put it (depending on its Next_is_Gap bit) into  
In_Schedule or In_Gap, enabling all Tx_Triggers and Rx_Triggers.  
A Potential Time Master will be in MState Current Time Master when it was the transmitter of  
the last Reference Message, else it will be in MState Backup Time Master.  
When all Potential Time Masters have finished Configuration, the node with the highest Time  
Master Priority in the network will become the Current Time Master.  
5.3 TTCAN Message Handling  
5.3.1 Message Reception  
In TTCAN, the handling of received message is the same as in Event driven CAN  
Communication, see chapter 4.1.3.1. The message’s MSC will be updated at the message’s  
Rx_Trigger(s) and gives additional means to check whether the received data arrived on time.  
5.3.2 Message Transmission  
In TTCAN, the handling of message to be transmitted is similar as in “Event driven CAN  
Communication”, see chapter 4.1.2. The differences for periodic messages and event driven  
messages are described in the following sections.  
5.3.2.1 Periodic Messages  
Neither TxRqst nor Newdat are changed from their preconfigured values. The application  
program has to update the data regularly and on time, synchronised to the Cycle Time.  
TTCAN’s CPU interface structure guarantees that no partially updated messages are  
transmitted. The message’s MSC provides information on the success of the transmission.  
The transmission may be temporarily disabled by resetting MsgLst or NewDat.  
5.3.2.2 Event Driven Messages  
The message data may be updated asynchronously to the Cycle Time, the transmission of the  
event driven message inside an Arbitrating Time Window is requested by setting both TxRqst  
and NewDat to ‘1’. The actual transmission is started time triggered when Cycle Time reaches  
the Time_Mark of the Tx_Trigger_Single or Tx_Trigger_Merged configured for the Message  
Object. Different from “Event driven CAN Communication”, the success of the transmission is  
indicated when the Message Handler resets NewDat while TxRqst remains unchanged. The  
MSC of an event driven message is not updated. When the transmission was not successful  
(lost arbitration or disturbance), it will be repeated next time (one of) its Tx_Trigger(s)  
become(s) active. When the transmission attempt was inside a Merged Arbitrating Time  
BOSCH  
- 66/77 -  
11.11.02  
 
         
User’s Manual  
TTCAN  
Revision 1.6  
Window, the retransmission may happen inside the same Window. The retransmission will not  
be started if NewDat is reset by the application program.  
When a Message Object for event driven messages is managed dynamically, the contents of a  
Message Object may be changed at the same time the transmission is requested. In that  
case, any previous content of the Message Object that is not transmitted successfully is lost.  
5.4 TTCAN Gap Control  
In the mode Event Synchronised Time Triggered Operation, the TTCAN message schedule of  
the System Matrix may be interrupted by Gaps. In those Gaps, all transmissions are stopped  
and the CAN bus remains idle. A Gap is finished when the next Reference Message starts a  
new Basic Cycle. A Gap starts at the end of a Basic Cycle that itself was started by a  
Reference Message with the bit Next_is_Gap=‘1’, so the Gaps are initiated by the current  
Time Master.  
The current Time Master has two options to initiate a Gap. A Gap can be initiated under  
software control when the application program writes NiG=‘1’ in the Gap Control register. A  
Gap can be initiated under hardware control when the application program enables (by writing  
EPE=‘1’) the EVENT_TRIGGER input pin. When a Reference Message is started and EPE is  
set, a high level at the EVENT_TRIGGER pin will cause Next_is_Gap=‘1’.  
When a Potential Time Master is in SyncST In_Gap, it has three options to intentionally finish  
a Gap. Under software control, writing FGp=‘1’ or under Hardware control, a low level at the  
EVENT_TRIGGER pin will restart the schedule. The third option is a time triggered restart  
when the application program writes TMG=‘1, controlled by the Time Mark register. Neither of  
these options can cause a Basic Cycle to be interrupted with a Reference Message.  
Any Potential Time Master will finish a Gap when it reaches its Tx_Ref_Trigger_Gap,  
assuming that the event to synchronise on did not occur in time.  
In the mode Strictly Time Triggered Operation, the bit Next_is_Gap=‘1’ in the Reference  
Message will be ignored, as well as the EVENT_TRIGGER pin and the bits NiG, EoG, and  
TMG in the Gap Control register.  
5.5 Stopwatch  
Although the application program can read the Local Time, Cycle Time, or Global Time  
registers any time, the Stopwatch register offers the possibility to time external events without  
any action by the application program.  
To enable the Stopwatch, the application program first has to define Local Time, Cycle Time,  
or Global Time as the Stopwatch source by writing SWS in the TT Clock Control Register.  
When SWS is > 0 and SWE in the TT Interrupt Vector register is ‘0’, the actual value of the  
time selected by SWS will be copied into Stop_Watch on the next rising edge of the  
STOP_WATCH_TRIGGER pin and SWE will be set to ‘1’.  
After the application program has read Stop_Watch, it may enable the next Stopwatch timing  
by resetting SWE to ‘0’.  
5.6 Local Time, Cycle Time, and Global Time and External Clock Synchronisation  
The Local Time is a Cyclic Counter consisting of a 16-bit integer part and a 3-bit fractional  
part. The integer part (the “Macro Tick”) is incremented once each NTU. The fractional part  
BOSCH  
- 67/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
(the “Micro Tick”) is incremented eight times each NTU, or, when TUR becomes <8 by drift  
compensation or by configuration for TTCAN Level 1, it is incremented four times each NTU.  
Figure 19 describes the synchronisation of the Cycle Time and Global Time, performed in the  
same manner by all TTCAN nodes, including the Time Master. Any message received or  
transmitted invokes a capture of the Local Time taken at the message’s Frame  
Synchronisation Event. This Frame Synchronisation Event occurs at the Sample Point of each  
Start of Frame (SoF) bit and causes the Local Time to be loaded into the Sync_Mark register.  
NTU  
Sync_Mark  
Ref_Mark  
Reference Message  
Master_Ref_Mark  
Local Time  
Frame Syn-  
chronisation  
Sync_Mark  
Reference  
Message Valid  
Ref_Mark  
Local Time Local_Offset  
Cycle Time  
Global Time  
Figure 19: Cycle Time and Global Time Synchronisation  
Whenever a valid reference message is transmitted or received, the contents of the  
Sync_Mark register is loaded into the Ref_Mark register. The difference between the actual  
value of the Ref_Mark and the local time is the cycle time (Cycle Time= Local Time–  
Ref_Mark).  
The Global Time exists for TTCAN Level 2 only, in Level 1 it is invalid. After Configuration, a  
Potential Time Master will use its own Local Time as Global Time. The time master  
establishes its own local time as global time by transmitting its own Ref_Marks in the  
Reference Message, as Master_Ref_Marks.  
A node that receives a Reference Message calculates its Local_Offset to the Global Time by  
comparing (see figure 19) their local Ref_Mark with the received Master_Ref_Mark. The  
node’s view of the Global Time is Local Time + Local_Offset. In a Potential Time Master that  
has never received another Time Master’s Reference Message, Local_Offset will be zero.  
When a node becomes the current Time Master after first having received other Reference  
Messages, Local_Offset will be frozen at its last value. In the time receiving nodes,  
Local_Offset may be subject to small adjustments, due to clock drift, when another node  
becomes Time Master, or when there is a Global Time discontinuity, signalled by the Disc_Bit  
in the Reference Message. With the exception of Global Time discontinuity, the Global Time  
provided to the application program in the Global Time register will be smoothed by a low-pass  
filtering, avoiding un-reasonableness in its integer part.  
BOSCH  
- 68/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
Start of  
Basic Cycle  
pervious  
cutal  
pervious  
cutal  
?
Calibration of  
Time Unit Ratio  
= 1  
Figure 20: TTCAN Level 2 Drift Compensation  
Figure 20 describes how in TTCAN Level 2 each time receiving node compensates the drift  
between its own local clock and the Time Master’s clock by comparing the length of a Basic  
Cycle in Local Time and in Global Time. If there is a difference between the two values and the  
Disc_Bit in the Reference Message is not set, a new value for NumAct is calculated. If the  
Synchronisation Deviation SD = |NumCfg-NumAct|SDL (Synchronisation Deviation Limit),  
the new value for NumAct takes effect. Else the automatic drift compensation is suspended.  
In TTCAN Level 2, QCS in the Clock Control register shows whether the automatic drift  
compensation is active or suspended. In TTCAN Level 1, QCS is always ‘1’.  
The current Time Master may synchronise its local clock speed and the Global Time phase to  
an external clock source. Both actions require that EECS in the Operating Mode Register is  
set.  
The Stopwatch (see chapter 3.5.18 and chapter 5.5) may be used to measure the difference in  
clock speed between the local clock and the external clock. The local clock speed is adjusted  
by first writing the newly calculated NumCfg value (DenomCfg cannot be updated) into the  
TUR Numerator Configuration register. The new value takes effect by writing ‘1’ to the ECS bit  
of the Clock Control register.  
The Global Time phase is adjusted by first writing the phase offset into the Global Time Preset  
register. The new value takes effect by writing ‘1’ to the SGT bit of the Clock Control register.  
The first Reference Message transmitted after the Global Time phase adjustment will contain  
the Disc_Bit=‘1’.  
QGTP in the Clock Control register shows whether the node’s Global Time is in phase with the  
Time Master’s Global Time. QGTP is permanently ‘0’ in TTCAN Level 1 and when the  
Synchronisation Deviation Limit is exceeded in TTCAN Level 2 (QCS=‘0’). It is temporarily ‘0’  
while the Global Time is low-pass filtered to avoid an un-reasonableness in the value provided  
to the application. There is no low-pass filtering when the last Reference Message’s contained  
a Disc_Bit=‘1’ or when QCS=‘0’.  
5.7 TTCAN Interrupt and Error Handling  
The TTCAN module provides the same interrupts as the C_CAN module (see chapter 4.3.1)  
as well as the additional TT Interrupt Vector.  
BOSCH  
- 69/77 -  
11.11.02  
 
   
User’s Manual  
TTCAN  
Revision 1.6  
The TT Interrupt Vector consists of four segments, each four bits long. Each of the bits of the  
TT Interrupt Vector can be separately enabled by a corresponding bit in the TT Interrupt  
Enable register. Once a bit of the TT Interrupt Vector is set, it will remain set until the  
application program writes a ‘0’ to this bit.  
The first segment consists of CfE, ApW, Wtr, and IWT. Each of these interrupts indicates a  
fatal error condition where the CAN communication is stopped. With the exception of IWT (see  
chapter 5.2), these error conditions require a re-configuration of the TTCAN module before the  
communication can be restarted.  
The second segment consists of CEL, TxO, TxU, and GTE. Each of these interrupts indicates  
an error condition where the CAN communication is disturbed. If they are caused by a  
transient failure, e.g. by disturbance on the CAN bus, they will be handled by the TTCAN  
protocol’s failure handling and do not require intervention by the application program.  
The third segment consists of Dis, GTW, SWE, and TMI. The first two interrupts are caused by  
Global Time events (Level 2 only) that require a reaction by the application program. The Stop  
Watch Event and the Time Mark Interrupt provide feedback to the application program when  
the application has requested the timing of external events or the notification on reaching a  
specific time. The Time Mark Interrupt can also be used to finish a Gap.  
The fourth segment consists of Gap, CSM, SSM, and SBC. These interrupts provide a means  
to synchronise the application program to the communication schedule.  
5.8 Configuration Example  
This is a configuration example for a TTCAN system consisting of three nodes (M0, M1, and  
S0) operating in TTCAN level 2 at a bit rate of 1 MBit/s. All three nodes have a system clock  
frequency of 10 MHz, the network time unit NTU is 1µs. Two nodes (M0 and M1) are potential  
time masters, the third node S0 is operating as a time slave.  
0x00A0 0x0140 0x01E0 0x0280 0x0320 0x03E6 0x0540 0x2000 0x2200  
0 M0_Msg2 S0_Msg2 M1_Msg2 Merged_Arb_Win  
1 S0_Msg3 S0_Msg2 M0_Msg3 M1_Msg3 Arb_Win1  
Ref_Msg Watch Ref_Gap Watch_Gap  
2 M0_Msg2 S0_Msg2 M1_Msg2 Arb_Win2 M1_Msg4  
3 S0_Msg3 S0_Msg2 M0_Msg3 M1_Msg3 Arb_Win3  
The System Matrix consists of four Basic Cycles 03, each Basic Cycle has five transmission  
columns at Cycle Time 0x00A0, 0x0140, 0x01E0, 0x0280, and 0x320. The length of the Basic  
Cycle is 0x03E8 NTUs=1000µs=1ms. M0 transmits the messages M0_Msg2 and M0_Msg3  
in exclusive time windows. M1 transmits the messages M1_Msg2, M1_Msg3, and M1_Msg4  
in exclusive time windows. S0 transmits the messages S0_Msg2 and S0_Msg3 in exclusive  
time windows. All nodes may transmit in the single or merged arbitrating time windows.  
M0 checks whether M1_Msg2 and S0_Msg2 are received on time. M1 checks whether  
M0_Msg3 and S0_Msg3 are received on time. S0 checks whether M0_Msg2 and M1_Msg4  
are received on time.  
The messages in the arbitrating time windows are transmitted event-driven, there is no  
Rx_Trigger to check for their reception.  
The time between the trigger for the Reference Message and the Watch_Trigger (and between  
Tx_Ref_Trigger_Gap and Watch_Trigger_Gap in case of a time gap) is long enough to allow  
for the retransmission of a disturbed Reference Message.  
BOSCH  
- 70/77 -  
11.11.02  
 
 
User’s Manual  
TTCAN  
Revision 1.6  
The general configuration of the three nodes is identical, there are differences in the Operation  
Mode, the TT Matrix Limits, the Message RAM, and the Trigger Memory. Note that the CPU  
has to wait after each write access to the IF1 Command Request Register for the requested  
transfer to be completed (check of Busy bit).  
Line  
Ad  
Register  
Remark  
M0  
M1  
S0  
1 00  
2 02  
3 02  
4 06  
5 0C  
6 28  
7 66  
8 2A  
9 2C  
CAN Control  
CAN Status  
enable configuration  
0041  
read register to check reason for (re-?)configuration  
CAN Status  
clear LEC  
0007  
Bit Timing  
bit time = 10 tq = 1 µs  
1 tq=clock period = 100 ns  
configuration mode  
1640  
BRP Extension  
TT Operation Mode  
TT Clock Control  
TT Matrix Limits1  
TT Matrix Limits2  
0000  
0001  
disable clock functions  
Tx_Triggers in Matrix Cycle  
RDLC & TEW & CCM  
0000  
0009 000A 000B  
4703  
00FF  
10 2E TT Application Watchdog Limit limit=0xFF00NTU =65ms  
11 30  
12 32  
13 56  
14 58  
15 6C  
16 6E  
17 12  
18 14  
19 16  
20 18  
21 1A  
22 1C  
23 1E  
24 20  
25 22  
26 24  
27 10  
28 16  
29 1A  
30 1C  
31 10  
32 1A  
33 10  
34 1A  
35 10  
36 1A  
TT Interrupt Enable  
TT Interrupt Vector  
TUR-NumeratorCfg  
TUR-DenominatorCfg  
TT Time Mark  
enable error interrupts  
clear all interrupts  
F000  
0000  
FFFE  
0x1FFFE clock periods =  
0x3333 NTU; NTU = 1 µs  
3333  
generate TMI at Time Mark  
disable gap functions  
0100 0200 0300  
0000  
TT Gap Control  
IF1 Command Mask  
IF1 Mask1  
write Mask, Arb, Control, Data  
00F3  
FFFF  
3 LSB of 11-bit Reference Mes-  
sage identifier masked  
IF1 Mask2  
9FE3  
0000  
A3C0  
9084  
DFE3  
83C0  
IF1 Arbitration1  
MsgVal, 11-bit id, Dir=Tx/Rx,  
Ref_Msg identifier=0F0  
IF1 Arbitration2  
IF1 Message Control  
IF1 Message Data A1  
IF1 Message Data A2  
IF1 Message Data B1  
IF1 Message Data B2  
IF1 Command Request  
IF1 Mask2  
NewDat, UMask, EoB, DLC=4  
FACE  
B055  
FEED  
CAFE  
0001  
some bytes for initialisation  
Ref_Msg in message object 1  
all bits must match  
FFFF  
IF1 Arbitration2  
MsgVal, Dir=Tx, xx_Msg2 id AC08 AC48 AC88  
IF1 Message Control  
IF1 Command Request  
IF1 Arbitration2  
NewDat, EoB, DLC=8  
8088  
0002  
xx_Msg2 in message object 2  
MsgVal, Dir=Tx, xx_Msg3 id AC0C AC4C AC8C  
xx_Msg3 in message object 3 0003  
MsgVal, Dir=Tx, M1_Msg4 id 0000 AC50 0000  
IF1 Command Request  
IF1 Arbitration2  
IF1 Command Request  
IF1 Arbitration2  
M1_Msg4 in message object 4  
0004  
4FFF  
not valid, Dir=Tx, dummy id  
BOSCH  
- 71/77 -  
11.11.02  
 
User’s Manual  
TTCAN  
Revision 1.6  
Line  
Ad  
Register  
Remark  
M0  
M1  
S0  
37 1C  
38 10  
39 10  
40 10  
41 10  
42 1A  
43 1C  
44 10  
45 1A  
46 10  
47 14  
48 16  
49 18  
50 1A  
51 1C  
52 10  
53 1C  
54 10  
55 22  
56 24  
57 0E  
58 22  
59 24  
60 0E  
61 22  
62 24  
63 0E  
64 22  
65 24  
66 0E  
67 22  
68 24  
69 0E  
70 22  
71 24  
72 0E  
73 22  
74 24  
75 0E  
76 22  
IF1 Message Control  
IF1 Command Request  
IF1 Command Request  
IF1 Command Request  
IF1 Command Request  
IF1 Arbitration2  
EoB, DLC=8 (for arb. message)  
Arb_Msg1 for message object 5  
Arb_Msg2 for message object 6  
Arb_Msg3 for message object 7  
set objects 816 to not valid  
0088  
0005  
0006  
0007  
00080010  
MsgVal, Dir=Rx, xx_Msgx id 8C48 8C0C 8C08  
IF1 Message Control  
IF1 Command Request  
IF1 Arbitration2  
EoB, DLC=8 (receive object)  
0088  
0011  
xx_Msgx in message object 17  
MsgVal, Dir=Rx, xx_Msgx id 8C88 8C8C 8C50  
IF1 Command Request  
IF1 Mask1  
xx_Msgx in message object 18  
0012  
0000  
all bits masked except Dir  
IF1 Mask2  
4000  
IF1 Arbitration1  
0000  
MsgVal, Dir=Tx/Rx  
IF1 Arbitration2  
A000  
IF1 Message Control  
IF1 Command Request  
IF1 Message Control  
IF1 Command Request  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
UMask, DLC=0, start of FIFO  
objects 1931 are Rx-FIFO  
UMask, EoB, end of FIFO  
object 32 is end of Rx-FIFO  
Type & Msg & Cycle_Code  
Time_Mark  
1000  
0013001F  
1080  
0020  
4202 D203 4303  
00A0 0138 00A0  
8000  
write trigger 0  
Type & Msg & Cycle_Code  
Time_Mark  
D200 4202 D102  
01D8 01E0 0138  
8001  
write trigger 1  
Type & Msg & Cycle_Code  
Time_Mark  
4303 D103 4200  
01E0 0278 0140  
8002  
write trigger 2  
Type & Msg & Cycle_Code  
Time_Mark  
D102 6504 6504  
0278 0280 0280  
8003  
write trigger 3  
Type & Msg & Cycle_Code  
Time_Mark  
6504 4303 4606  
0280 0280 0280  
8004  
write trigger 4  
Type & Msg & Cycle_Code  
Time_Mark  
4606 4606 4504  
0280 0280 0320  
8005  
write trigger 5  
Type & Msg & Cycle_Code  
Time_Mark  
4504 4504 4703  
0320 0320 0320  
8006  
write trigger 6  
Type & Msg & Cycle_Code  
4703 4703 D206  
BOSCH  
- 72/77 -  
11.11.02  
 
User’s Manual  
TTCAN  
Revision 1.6  
Line  
Ad  
Register  
Remark  
M0  
M1  
S0  
77 24  
78 0E  
79 22  
80 24  
81 0E  
82 22  
83 24  
84 0E  
85 22  
86 24  
87 0E  
88 22  
89 24  
90 0E  
91 22  
92 24  
93 0E  
94 22  
95 24  
96 0E  
97 66  
98 28  
99 00  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
IF1 Message Data B1  
IF1 Message Data B2  
Trigger Memory Access  
TT Clock Control  
Time_Mark  
0320 0320 03F0  
8007  
write trigger 7  
Type & Msg & Cycle_Code  
Time_Mark  
0100 4406 8000  
03E6 0320 0540  
8008  
write trigger 8  
Type & Msg & Cycle_Code  
Time_Mark  
8000 0100 A000  
0540 03E6 2200  
8009  
write trigger 9  
Type & Msg & Cycle_Code  
Time_Mark  
2100 8000 E000  
2000 0540 FFFF  
800A  
write trigger 10  
Type & Msg & Cycle_Code  
Time_Mark  
A000 2100 E000  
2200 2000 FFFF  
800B  
write trigger 11  
Type & Msg & Cycle_Code  
Time_Mark  
E000 A000 E000  
FFFF 2200 FFFF  
800C  
write trigger 12  
Type & Msg & Cycle_Code  
Time_Mark (EndofList)  
write trigger 13…32  
ldSDL=2, CT-TMI, GT-SW  
E000  
FFFF  
800D801F  
474C  
TT Operation Mode  
CAN Control  
R_T_O, TM, L2, TTMode_3 008B 08CB 7F7B  
start operating, enable interrupt 0002  
In the Message RAM, the first Message Object is reserved for the Reference Message. The  
objects 2 to 16 are transmit objects, the objects 17 to 32 are receive objects.  
M0  
M1  
S0  
1
Reference Message, Id=0F00F7  
2 M0_Msg2, Id=302, Tx  
3 M0_Msg3, Id=303, Tx  
M1_Msg2, Id=312, Tx  
M1_Msg3, Id=313, Tx  
M1_Msg4, Id=314, Tx  
Tx in Merged_Arb_Win  
Tx in Arb_Win2  
S0_Msg2, Id=322, Tx  
S0_Msg3, Id=323, Tx  
not valid  
4
not valid  
5 Tx in Merged_Arb_Win  
6 Tx in Arb_Win2  
Tx in Merged_Arb_Win  
Tx in Arb_Win2  
7 Tx in Arb_Win1 or 3  
Tx in Arb_Win1 or 3  
not valid  
Tx in Arb_Win1 or 3  
not valid  
816  
not valid  
17  
18  
M1_Msg2, Id=312, Rx  
S0_Msg2, Id=322, Rx  
Id=xxx, Rx-FIFO-Start  
Id=xxx, Rx-FIFO-End  
M0_Msg3, Id=303, Rx  
S0_Msg3, Id=323, Rx  
Id=xxx, Rx-FIFO-Start  
Id=xxx, Rx-FIFO-End  
M0_Msg2, Id=302, Rx  
M1_Msg4, Id=314, Rx  
Id=xxx, Rx-FIFO-Start  
Id=xxx, Rx-FIFO-End  
1931  
32  
BOSCH  
- 73/77 -  
11.11.02  
 
User’s Manual  
TTCAN  
Revision 1.6  
The transmit message objects 56, to be transmitted in the arbitrating time windows, may be  
controlled dynamically or may be restricted to specific messages. Their identifiers should have  
a lower priority than the Reference Message or the periodic messages.  
The Trigger Memory contains two triggers for the message object 5, so the transmission of the  
contents of this message object could start at the beginning of the merged arbitrating time  
window at 0x0280 or at the second trigger at 0x0320. The second trigger cannot start a  
second transmission if the first transmission was successful and the application did not  
request a second transmission.  
After the configuration, the TTCAN module synchronises itself to the TTCAN message  
schedule. S0 will wait for the first Reference Message to finish its initialisation. M0 and M1  
may reach Initialisation Watch Trigger and raise the IWT interrupt when one of them is the first  
node to finish configuration and does not get a dominant acknowledge bit for its transmitted  
Reference Message. In this case, the application program has to restart the TTCAN module  
by clearing the IWT bit.  
In the configuration, the transmit message objects for the arbitrating time windows are not yet  
activated, so there will not be any transmissions in the arbitrating time windows until the  
application program loads the transmit message objects and requests the transmission.  
The actual time master can control the synchronisation of the TTCAN network to external  
The nodes are configured to generate an event at their Time Mark interrupt outputs TMI at  
Cycle Time 0x0100, 0x0200, and 0x0300. These events are intended as triggers for time  
measurements and for the analysis of the message schedule.  
The nodes are configured to capture their Global Time at an event at their stopwatch trigger  
inputs SWT. The nodes’ Global Time can be monitored and compared when all SWT inputs  
are triggered synchronously.  
The application has to serve the Application Watchdog at least once in 65 ms, else the ApW  
interrupt is set and the TTCAN module enters TT Error Level “Fatal Error”, stopping all  
communication. This error requires a re-configuration. The Application Watchdog may be  
disabled during software development. The following modifications will disable the watchdog:  
Line 1 : CAN Control to 00C1; Line 1a: CAN Test Register to 0001  
Line 10 : Application Watchdog Limit to 0000  
Line 99 : CAN Control to 0082  
It might be useful for software development to copy (e.g. at the start of a Basic Cycle) the  
content of some of the TTCAN status registers (TT Master State, TT Error Level, TUR  
Numerator Actual, Clock Control, Gap Control, or Stop_Watch) into periodic messages that  
can be monitored with the usual CAN analysing tools.  
BOSCH  
- 74/77 -  
11.11.02  
 
User’s Manual  
TTCAN  
Revision 1.6  
6. CPU Interface  
The interface of the TTCAN module consist of two parts (see figure 21). The Generic Interface  
which is a fixed part of the TTCAN module and the Customer Interface which can be adapted  
to the customers requirements.  
Clock  
Reset  
CAN_CLK  
Customer  
Interface  
Generic  
Interface  
CAN_RESET  
RD_STATUS_REG_LOW  
DB_W  
(generic parameter)  
WR_<regx>_HIGH  
WR_<regx>_LOW  
<regx>_HIGH_DIN  
<regx>_LOW_DIN  
CAN_WR_B  
Control  
Buffers  
Address  
Decode  
CAN_SELECT  
Data Bus  
Control  
Address(7:0)  
DataIN  
CAN_ADDR  
MUX  
CAN_DATA_IN  
CAN_DATA_OUT  
regx  
regy  
DataOUT  
Interrupt  
Drivers  
CAN_INT  
CAN_WAIT_B  
(optional output)  
Figure 21: Structure of the module interface  
6.1 Customer Interface  
The purpose of the Customer Interface is to adapt the timings of the module-external signals  
to the timing requirements of the module and to buffer / drive the external signals. Number and  
names of the module ports depend on the Customer Interface used with the actual  
implementation.  
The Customer Interface also supplies the clock and reset signals for the module.  
8 MHz is the minimum clock frequency required to operate the TTCAN module with a bit rate  
of 1 MBit/s. The maximum clock frequency is dependent on synthesis constraints and on the  
technology which is used for synthesis. The read / write timing of the TTCAN module depends  
on the Customer Interface used with the actual implementation.  
Up to now three different Customer Interfaces are available for the TTCAN module. Two 16-bit  
interfaces to the AMBA APB bus from ARM and an 8-bit interface for the Motorola HC08  
controller. A detailed description of these interfaces can be found in the Module Integration  
Guide, also describing how to build new Customer Interfaces for other CPUs.  
manual_cpu_ifc.fm  
BOSCH  
- 75/77 -  
11.11.02  
 
     
User’s Manual  
TTCAN  
Revision 1.6  
6.2 Timing of the WAIT output signal  
If the Customer Interfaces is implemented with a wait-function, the CPU is halted while a  
message transfer is in progress between the IFx Registers and the Message RAM, when the  
module’s optional output port CAN_WAIT_B is at active low level. Figure 22 shows the timing  
of CAN_WAIT_B with respect to the modules internal clock CAN_CLK. The number of clock  
cycles needed for a transfer between the IFx Registers and the Message RAM can vary  
between 3 and 6 clock cycles depending on the state of the Message Handler (idle,  
acceptance filtering, load / store CAN message, ).  
3 - 6 CAN_CLK Cycles  
CAN_CLK  
CAN_WAIT_B  
Write Message-No. to IFx  
Command Request Register =>  
Busy = ‘1’  
Requested Data loaded  
into / from IFx Registers =>  
Busy = ‘0’  
Figure 22: Timing of WAIT output signal CAN_WAIT_B.  
The message transfer is also shown by the Busy bit in the high byte of the Command Request  
Register. The Busy bit is automatically set to ‘1’ by the command write operation to notify the  
CPU that a transfer is in progress. After a time of 3 to 6 CAN_CLK periods, the transfer  
between the Interface Register and the Message RAM has completed and the Busy bit is  
cleared to ‘0’. This time is at the upper limit when the message transfer coincides with a CAN  
message transmission start, acceptance filtering, or message storage. An IFx Register cannot  
be read or written while its Busy bit is set, but other registers may be accessed in that time.  
The waiting time is not dependent on the amount of data being transferred.  
6.3 Interrupt Timing  
Figure 23 shows the timing at the modules interrupt port CAN_INT (active low) with respect to  
the modules internal clock CAN_CLK.  
CAN_CLK  
CAN_INT  
Enabled Interrupt Flag set  
while IE = ‘1’  
Reset Interrupt Flag  
or write IE = ‘0’  
Figure 23: Timing of interrupt signal CAN_INT.  
If several interrupt flags of the TTCAN module are set (status interrupt, message interrupts),  
all interrupt flags have to be reset before the CAN_INT returns to passive level.  
BOSCH  
- 76/77 -  
11.11.02  
 
         
User’s Manual  
TTCAN  
Revision 1.6  
7. Appendix  
7.1 List of Figures  
EOF  
BOSCH  
- 77/77 -  
11.11.02  
manual_appendix.fm  
 
       

Black Decker Saw 381341 01 User Manual
Blanco Indoor Furnishings 501 111 User Manual
Blanco Indoor Furnishings 515 824 User Manual
Breville Blender BBL550 User Manual
Briggs Stratton Plumbing Product 073000 User Manual
Bush Hog Lawn Mower PHDC User Manual
Califone Portable Stereo System 2395IRPLC 6 User Manual
Canon Printer Accessories EP27 User Manual
Cateye Cyclometer OS10 User Manual
Child Craft Crib CCH0070109 00 User Manual